# # CMX-0 Nets File # # Front-Panel CTP LVDS Power Ground Bypass Cap Nets # --====================--------------------------------- # # # Original Rev. 2-Nov-2012 # Most Recent Rev. 27-Nov-2012 # # # # This file holds the nets that connect power, ground, # and the bypass capacitors to the Front Panel CTP LVDS # transceiver and level translators chips. # # # Power and ByPass for U69 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U69-7 U69-18 # U69 3.3V Vccb power NET 'BULK_2V5' U69-31 U69-42 # U69 2.5V Vcca power NET 'GROUND' U69-4 U69-10 # U69 Ground connections NET 'GROUND' U69-15 U69-21 # U69 Ground connections NET 'GROUND' U69-28 U69-34 # U69 Ground connections NET 'GROUND' U69-39 U69-45 # U69 Ground connections NET 'BULK_3V3' C532-2 C533-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C531-1 C534-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C532-1 C533-1 # ByPass Cap Ground connections NET 'GROUND' C531-2 C534-2 # ByPass Cap Ground connections # Power and ByPass for U70 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U70-7 U70-18 # U70 3.3V Vccb power NET 'BULK_2V5' U70-31 U70-42 # U70 2.5V Vcca power NET 'GROUND' U70-4 U70-10 # U70 Ground connections NET 'GROUND' U70-15 U70-21 # U70 Ground connections NET 'GROUND' U70-28 U70-34 # U70 Ground connections NET 'GROUND' U70-39 U70-45 # U70 Ground connections NET 'BULK_3V3' C536-2 C537-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C535-1 C538-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C536-1 C537-1 # ByPass Cap Ground connections NET 'GROUND' C535-2 C538-2 # ByPass Cap Ground connections # Power and ByPass for U71 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U71-7 U71-18 # U71 3.3V Vccb power NET 'BULK_2V5' U71-31 U71-42 # U71 2.5V Vcca power NET 'GROUND' U71-4 U71-10 # U71 Ground connections NET 'GROUND' U71-15 U71-21 # U71 Ground connections NET 'GROUND' U71-28 U71-34 # U71 Ground connections NET 'GROUND' U71-39 U71-45 # U71 Ground connections NET 'BULK_3V3' C540-2 C541-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C539-1 C542-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C540-1 C541-1 # ByPass Cap Ground connections NET 'GROUND' C539-2 C542-2 # ByPass Cap Ground connections # Power and ByPass for U72 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U72-7 U72-18 # U72 3.3V Vccb power NET 'BULK_2V5' U72-31 U72-42 # U72 2.5V Vcca power NET 'GROUND' U72-4 U72-10 # U72 Ground connections NET 'GROUND' U72-15 U72-21 # U72 Ground connections NET 'GROUND' U72-28 U72-34 # U72 Ground connections NET 'GROUND' U72-39 U72-45 # U72 Ground connections NET 'BULK_3V3' C544-2 C545-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C543-1 C546-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C544-1 C545-1 # ByPass Cap Ground connections NET 'GROUND' C543-2 C546-2 # ByPass Cap Ground connections # Power and ByPass for U73 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U73-7 U73-18 # U73 3.3V Vccb power NET 'BULK_2V5' U73-31 U73-42 # U73 2.5V Vcca power NET 'GROUND' U73-4 U73-10 # U73 Ground connections NET 'GROUND' U73-15 U73-21 # U73 Ground connections NET 'GROUND' U73-28 U73-34 # U73 Ground connections NET 'GROUND' U73-39 U73-45 # U73 Ground connections NET 'BULK_3V3' C548-2 C549-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C547-1 C550-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C548-1 C549-1 # ByPass Cap Ground connections NET 'GROUND' C547-2 C550-2 # ByPass Cap Ground connections # Power and ByPass for U74 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U74-7 U74-18 # U74 3.3V Vccb power NET 'BULK_2V5' U74-31 U74-42 # U74 2.5V Vcca power NET 'GROUND' U74-4 U74-10 # U74 Ground connections NET 'GROUND' U74-15 U74-21 # U74 Ground connections NET 'GROUND' U74-28 U74-34 # U74 Ground connections NET 'GROUND' U74-39 U74-45 # U74 Ground connections NET 'BULK_3V3' C552-2 C553-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C551-1 C554-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C552-1 C553-1 # ByPass Cap Ground connections NET 'GROUND' C551-2 C554-2 # ByPass Cap Ground connections # Power and ByPass for U75 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U75-7 U75-18 # U75 3.3V Vccb power NET 'BULK_2V5' U75-31 U75-42 # U75 2.5V Vcca power NET 'GROUND' U75-4 U75-10 # U75 Ground connections NET 'GROUND' U75-15 U75-21 # U75 Ground connections NET 'GROUND' U75-28 U75-34 # U75 Ground connections NET 'GROUND' U75-39 U75-45 # U75 Ground connections NET 'BULK_3V3' C556-2 C557-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C555-1 C558-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C556-1 C557-1 # ByPass Cap Ground connections NET 'GROUND' C555-2 C558-2 # ByPass Cap Ground connections # Power and ByPass for U76 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U76-7 U76-18 # U76 3.3V Vccb power NET 'BULK_2V5' U76-31 U76-42 # U76 2.5V Vcca power NET 'GROUND' U76-4 U76-10 # U76 Ground connections NET 'GROUND' U76-15 U76-21 # U76 Ground connections NET 'GROUND' U76-28 U76-34 # U76 Ground connections NET 'GROUND' U76-39 U76-45 # U76 Ground connections NET 'BULK_3V3' C560-2 C561-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C559-1 C562-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C560-1 C561-1 # ByPass Cap Ground connections NET 'GROUND' C559-2 C562-2 # ByPass Cap Ground connections # Power and ByPass for U77 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U77-7 U77-18 # U77 3.3V Vccb power NET 'BULK_2V5' U77-31 U77-42 # U77 2.5V Vcca power NET 'GROUND' U77-4 U77-10 # U77 Ground connections NET 'GROUND' U77-15 U77-21 # U77 Ground connections NET 'GROUND' U77-28 U77-34 # U77 Ground connections NET 'GROUND' U77-39 U77-45 # U77 Ground connections NET 'BULK_3V3' C564-2 C565-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C563-1 C566-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C564-1 C565-1 # ByPass Cap Ground connections NET 'GROUND' C563-2 C566-2 # ByPass Cap Ground connections # Power and ByPass for U78 74AVCAH164245 power is BULK_2V5 and BULK_3V3 NET 'BULK_3V3' U78-7 U78-18 # U77 3.3V Vccb power NET 'BULK_2V5' U78-31 U78-42 # U77 2.5V Vcca power NET 'GROUND' U78-4 U78-10 # U77 Ground connections NET 'GROUND' U78-15 U78-21 # U77 Ground connections NET 'GROUND' U78-28 U78-34 # U77 Ground connections NET 'GROUND' U78-39 U78-45 # U77 Ground connections NET 'BULK_3V3' C568-2 C569-2 # ByPass Cap 3.3V Vccb power NET 'BULK_2V5' C567-1 C570-1 # ByPass Cap 2.5V Vcca power NET 'GROUND' C568-1 C569-1 # ByPass Cap Ground connections NET 'GROUND' C567-2 C570-2 # ByPass Cap Ground connections # # U51:U67 CTP LVDS DS91M040 Transceivers # # DS91M040 +3.3V Power Connections NET 'BULK_3V3' U51-11 U51-12 U51-29 U51-30 NET 'BULK_3V3' U52-11 U52-12 U52-29 U52-30 NET 'BULK_3V3' U53-11 U53-12 U53-29 U53-30 NET 'BULK_3V3' U54-11 U54-12 U54-29 U54-30 NET 'BULK_3V3' U55-11 U55-12 U55-29 U55-30 NET 'BULK_3V3' U56-11 U56-12 U56-29 U56-30 NET 'BULK_3V3' U57-11 U57-12 U57-29 U57-30 NET 'BULK_3V3' U58-11 U58-12 U58-29 U58-30 NET 'BULK_3V3' U59-11 U59-12 U59-29 U59-30 NET 'BULK_3V3' U60-11 U60-12 U60-29 U60-30 NET 'BULK_3V3' U61-11 U61-12 U61-29 U61-30 NET 'BULK_3V3' U62-11 U62-12 U62-29 U62-30 NET 'BULK_3V3' U63-11 U63-12 U63-29 U63-30 NET 'BULK_3V3' U64-11 U64-12 U64-29 U64-30 NET 'BULK_3V3' U65-11 U65-12 U65-29 U65-30 NET 'BULK_3V3' U66-11 U66-12 U66-29 U66-30 NET 'BULK_3V3' U67-11 U67-12 U67-29 U67-30 NET 'BULK_3V3' U68-11 U68-12 U68-29 U68-30 # U51:U67 CTP LVDS DS91M040 Transceivers # # DS91M040 GROUND Connections NET 'GROUND' U51-31 NET 'GROUND' U52-31 NET 'GROUND' U53-31 NET 'GROUND' U54-31 NET 'GROUND' U55-31 NET 'GROUND' U56-31 NET 'GROUND' U57-31 NET 'GROUND' U58-31 NET 'GROUND' U59-31 NET 'GROUND' U51-33 U51-34 U51-35 U51-36 NET 'GROUND' U52-33 U52-34 U52-35 U52-36 NET 'GROUND' U53-33 U53-34 U53-35 U53-36 NET 'GROUND' U54-33 U54-34 U54-35 U54-36 NET 'GROUND' U55-33 U55-34 U55-35 U55-36 NET 'GROUND' U56-33 U56-34 U56-35 U56-36 NET 'GROUND' U57-33 U57-34 U57-35 U57-36 NET 'GROUND' U58-33 U58-34 U58-35 U58-36 NET 'GROUND' U59-33 U59-34 U59-35 U59-36 NET 'GROUND' U60-31 NET 'GROUND' U61-31 NET 'GROUND' U62-31 NET 'GROUND' U63-31 NET 'GROUND' U64-31 NET 'GROUND' U65-31 NET 'GROUND' U66-31 NET 'GROUND' U67-31 NET 'GROUND' U68-31 NET 'GROUND' U60-33 U60-34 U60-35 U60-36 NET 'GROUND' U61-33 U61-34 U61-35 U61-36 NET 'GROUND' U62-33 U62-34 U62-35 U62-36 NET 'GROUND' U63-33 U63-34 U63-35 U63-36 NET 'GROUND' U64-33 U64-34 U64-35 U64-36 NET 'GROUND' U65-33 U65-34 U65-35 U65-36 NET 'GROUND' U66-33 U66-34 U66-35 U66-36 NET 'GROUND' U67-33 U67-34 U67-35 U67-36 NET 'GROUND' U68-33 U68-34 U68-35 U68-36 # # Bypass Capacitors C571:C578 on the # DS91M040 LVDS Transceivers U51:U67 # NET 'BULK_3V3' C571-1 C572-1 C573-1 # ByPass Cap on 3.3V power NET 'BULK_3V3' C574-1 C575-1 C576-1 # ByPass Cap on 3.3V power NET 'BULK_3V3' C577-1 C578-1 C579-1 # ByPass Cap on 3.3V power NET 'BULK_3V3' C580-1 C581-1 C582-1 # ByPass Cap on 3.3V power NET 'BULK_3V3' C583-1 C584-1 C585-1 # ByPass Cap on 3.3V power NET 'BULK_3V3' C586-1 C587-1 C588-1 # ByPass Cap on 3.3V power NET 'GROUND' C571-2 C572-2 C573-2 # and its Ground connection NET 'GROUND' C574-2 C575-2 C576-2 # and its Ground connection NET 'GROUND' C577-2 C578-2 C579-2 # and its Ground connection NET 'GROUND' C580-2 C581-2 C582-2 # and its Ground connection NET 'GROUND' C583-2 C584-2 C585-2 # and its Ground connection NET 'GROUND' C586-2 C587-2 C588-2 # and its Ground connection