# # Mini_POD Net List File # # Mini_POD Receiver and Transmitter Nets # ----------------------------------------------------- # # Initial Rev. 16-Feb-2018 # Current Rev. 10-Apr-2018 # # # This file holds all nets associated the MiniPOD receiver and # and transmitter modules # # # # MiniPOD Receiver Module Nets # -------==========----------- # # # Connect MiniPOD Receiver Outputs for # Fibers: 1,3,5,7,9,11 to J1 MGT Receivers # # Fibers: 1, 7, 9 have Polarity Flips # # Polarity Flips are implemented by # swapping pins at the J1 connector. # NET 'Mini_POD_Rec_D1_to_Cap_DIR' Rec_MP-F1 C27-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D1_to_Cap_CMP' Rec_MP-F2 C28-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D1_to_MGT_DIR' C27-2 J1-31 (NET_TYPE, 'DIFF_PAIR_HS') # Polarity NET 'Mini_POD_Cap_D1_to_MGT_CMP' C28-2 J1-29 (NET_TYPE, 'DIFF_PAIR_HS') # Flip NET 'Mini_POD_Rec_D3_to_Cap_DIR' Rec_MP-J2 C31-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D3_to_Cap_CMP' Rec_MP-H2 C32-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D3_to_MGT_DIR' C31-2 J1-25 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D3_to_MGT_CMP' C32-2 J1-27 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D5_to_Cap_DIR' Rec_MP-J4 C35-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D5_to_Cap_CMP' Rec_MP-H4 C36-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D5_to_MGT_DIR' C35-2 J1-21 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D5_to_MGT_CMP' C36-2 J1-23 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D7_to_Cap_DIR' Rec_MP-J6 C39-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D7_to_Cap_CMP' Rec_MP-H6 C40-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D7_to_MGT_DIR' C39-2 J1-19 (NET_TYPE, 'DIFF_PAIR_HS') # Polarity NET 'Mini_POD_Cap_D7_to_MGT_CMP' C40-2 J1-17 (NET_TYPE, 'DIFF_PAIR_HS') # Flip NET 'Mini_POD_Rec_D9_to_Cap_DIR' Rec_MP-J8 C43-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D9_to_Cap_CMP' Rec_MP-H8 C44-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D9_to_MGT_DIR' C43-2 J1-15 (NET_TYPE, 'DIFF_PAIR_HS') # Polarity NET 'Mini_POD_Cap_D9_to_MGT_CMP' C44-2 J1-13 (NET_TYPE, 'DIFF_PAIR_HS') # Flip NET 'Mini_POD_Rec_D11_to_Cap_DIR' Rec_MP-F9 C47-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D11_to_Cap_CMP' Rec_MP-F8 C48-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D11_to_MGT_DIR' C47-2 J1-9 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D11_to_MGT_CMP' C48-2 J1-11 (NET_TYPE, 'DIFF_PAIR_HS') # # Connect MiniPOD Receiver Outputs for # Fibers: 0,2,4,6,8,10 to J3 MGT Receivers # # Fiber 2 has Polarity Flip # # Polarity Flips are implemented by # swapping pins at the J3 connector. # NET 'Mini_POD_Rec_D10_to_Cap_DIR' Rec_MP-D9 C45-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D10_to_Cap_CMP' Rec_MP-D8 C46-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D10_to_MGT_DIR' C45-2 J3-12 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D10_to_MGT_CMP' C46-2 J3-10 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D8_to_Cap_DIR' Rec_MP-A8 C41-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D8_to_Cap_CMP' Rec_MP-B8 C42-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D8_to_MGT_DIR' C41-2 J3-16 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D8_to_MGT_CMP' C42-2 J3-14 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D6_to_Cap_DIR' Rec_MP-A6 C37-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D6_to_Cap_CMP' Rec_MP-B6 C38-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D6_to_MGT_DIR' C37-2 J3-20 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D6_to_MGT_CMP' C38-2 J3-18 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D4_to_Cap_DIR' Rec_MP-A4 C33-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D4_to_Cap_CMP' Rec_MP-B4 C34-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D4_to_MGT_DIR' C33-2 J3-24 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D4_to_MGT_CMP' C34-2 J3-22 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D2_to_Cap_DIR' Rec_MP-A2 C29-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D2_to_Cap_CMP' Rec_MP-B2 C30-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D2_to_MGT_DIR' C29-2 J3-26 (NET_TYPE, 'DIFF_PAIR_HS') # Polarity NET 'Mini_POD_Cap_D2_to_MGT_CMP' C30-2 J3-28 (NET_TYPE, 'DIFF_PAIR_HS') # Flip NET 'Mini_POD_Rec_D0_to_Cap_DIR' Rec_MP-D1 C25-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Rec_D0_to_Cap_CMP' Rec_MP-D2 C26-1 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D0_to_MGT_DIR' C25-2 J3-32 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Cap_D0_to_MGT_CMP' C26-2 J3-30 (NET_TYPE, 'DIFF_PAIR_HS') # # Receiver MiniPOD Ground Pin Connections # NET 'GROUND' Rec_MP-A1 Rec_MP-B1 NET 'GROUND' Rec_MP-A3 Rec_MP-B3 NET 'GROUND' Rec_MP-A5 Rec_MP-B5 NET 'GROUND' Rec_MP-A7 Rec_MP-B7 NET 'GROUND' Rec_MP-A9 Rec_MP-B9 NET 'GROUND' Rec_MP-C1 Rec_MP-C2 NET 'GROUND' Rec_MP-C8 Rec_MP-C9 NET 'GROUND' Rec_MP-D3 Rec_MP-D7 NET 'GROUND' Rec_MP-E1 Rec_MP-E2 NET 'GROUND' Rec_MP-E8 Rec_MP-E9 NET 'GROUND' Rec_MP-F3 Rec_MP-F7 NET 'GROUND' Rec_MP-G1 Rec_MP-G2 NET 'GROUND' Rec_MP-G8 Rec_MP-G9 NET 'GROUND' Rec_MP-H1 Rec_MP-J1 NET 'GROUND' Rec_MP-H3 Rec_MP-J3 NET 'GROUND' Rec_MP-H5 Rec_MP-J5 NET 'GROUND' Rec_MP-H7 Rec_MP-J7 NET 'GROUND' Rec_MP-H9 Rec_MP-J9 NET 'GROUND' Rec_MP-SCRW1 Rec_MP-SCRW2 # # Receiver Module TWS Bus Address Signals # # Address 0 NET 'GROUND' Rec_MP-G3 # Address 1 NET 'GROUND' Rec_MP-E3 # Address 2 NET 'GROUND' Rec_MP-C3 # # Receiver: Reset, SDA, SCL, and Interrupt Signals # # Pull-Up Resistors and FPGA Mezz Connections # NET 'MP_Rec_INTR' Rec_MP-D6 R445-1 J3-80 NET 'MP_Rec_SDA' Rec_MP-D4 R446-1 J3-78 NET 'MP_Rec_SCL' Rec_MP-E6 R447-1 J3-74 NET 'MP_Rec_RESET' Rec_MP-E4 R448-1 J3-72 NET 'MP_Rec_3V3' R445-2 R446-2 R447-2 R448-2 # # Receiver MiniPOD Power Supply Nets # NET 'MP_Rec_3V3' Rec_MP-C4 Rec_MP-C5 Rec_MP-C6 NET 'MP_Rec_2V5' Rec_MP-F4 NET 'MP_Rec_2V5' Rec_MP-G4 Rec_MP-G5 Rec_MP-G6 # # Receiver MiniPOD 2.5 Volt Power Filter NET 'BULK_2V5' L431-1 C431-1 C432-2 C433-1 NET 'GROUND' C431-2 C432-1 C433-2 NET 'MP_Rec_2V5' L431-2 C434-2 C435-1 C436-1 NET 'GROUND' C434-1 C435-2 R431-1 NET 'MP_Rec_2V5_FLT_RES' C436-2 R431-2 # # Receiver MiniPOD 3.3 Volt Power Filter NET 'BULK_3V3' L441-1 C441-1 C442-2 C443-1 NET 'GROUND' C441-2 C442-1 C443-2 NET 'MP_Rec_3V3' L441-2 C444-2 C445-1 C446-1 NET 'GROUND' C444-1 C445-2 R441-1 NET 'MP_Rec_3V3_FLT_RES' C446-2 R441-2 # # Now the Do Not Connect Pins # on the Receiver MiniPOD # NET 'No_Conn_Rec_MP_C7' Rec_MP-C7 NET 'No_Conn_Rec_MP_D5' Rec_MP-D5 NET 'No_Conn_Rec_MP_E5' Rec_MP-E5 NET 'No_Conn_Rec_MP_E7' Rec_MP-E7 NET 'No_Conn_Rec_MP_F5' Rec_MP-F5 NET 'No_Conn_Rec_MP_F6' Rec_MP-F6 NET 'No_Conn_Rec_MP_G7' Rec_MP-G7 ########################################### # # # Receive Above Transmit Below # # # ########################################### # # # MiniPOD Transmitter Module Nets # -------=============----------- # # Connect MiniPOD Transmitter Data Inputs for # Fibers 0 through 3 to J1 MGT Transmitters # # Fiber 0 has a Polarity Flips # # Polarity Flips are implemented by # swapping pins at the J1 connector. # NET 'Mini_POD_Trans_D2_DIR' Trans_MP-A2 J1-18 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Trans_D2_CMP' Trans_MP-B2 J1-20 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Trans_D0_DIR' Trans_MP-D1 J1-24 (NET_TYPE, 'DIFF_PAIR_HS') # Polarity NET 'Mini_POD_Trans_D0_CMP' Trans_MP-D2 J1-22 (NET_TYPE, 'DIFF_PAIR_HS') # Flip NET 'Mini_POD_Trans_D1_DIR' Trans_MP-F1 J1-26 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Trans_D1_CMP' Trans_MP-F2 J1-28 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Trans_D3_DIR' Trans_MP-H2 J1-30 (NET_TYPE, 'DIFF_PAIR_HS') NET 'Mini_POD_Trans_D3_CMP' Trans_MP-J2 J1-32 (NET_TYPE, 'DIFF_PAIR_HS') # # Transmitter MiniPOD Ground Pin Connections # NET 'GROUND' Trans_MP-A1 Trans_MP-B1 NET 'GROUND' Trans_MP-A3 Trans_MP-B3 NET 'GROUND' Trans_MP-A5 Trans_MP-B5 NET 'GROUND' Trans_MP-A7 Trans_MP-B7 NET 'GROUND' Trans_MP-A9 Trans_MP-B9 NET 'GROUND' Trans_MP-C1 Trans_MP-C2 NET 'GROUND' Trans_MP-C8 Trans_MP-C9 NET 'GROUND' Trans_MP-D3 Trans_MP-D7 NET 'GROUND' Trans_MP-E1 Trans_MP-E2 NET 'GROUND' Trans_MP-E8 Trans_MP-E9 NET 'GROUND' Trans_MP-F3 Trans_MP-F7 NET 'GROUND' Trans_MP-G1 Trans_MP-G2 NET 'GROUND' Trans_MP-G8 Trans_MP-G9 NET 'GROUND' Trans_MP-H1 Trans_MP-J1 NET 'GROUND' Trans_MP-H3 Trans_MP-J3 NET 'GROUND' Trans_MP-H5 Trans_MP-J5 NET 'GROUND' Trans_MP-H7 Trans_MP-J7 NET 'GROUND' Trans_MP-H9 Trans_MP-J9 NET 'GROUND' Trans_MP-SCRW1 Trans_MP-SCRW2 # # Transmitter Module TWS Bus Address Signals # # Address 0 NET 'GROUND' Trans_MP-G3 # Address 1 NET 'GROUND' Trans_MP-E3 # Address 2 NET 'GROUND' Trans_MP-C3 # # Transmitter: Reset, SDA, SCL, and Interrupt Signals # # Pull-Up Resistors and FPGA Mezz Connections # NET 'MP_Trans_INTR' Trans_MP-D6 R425-1 J3-66 NET 'MP_Trans_SDA' Trans_MP-D4 R426-1 J3-60 NET 'MP_Trans_SCL' Trans_MP-E6 R427-1 J3-54 NET 'MP_Trans_RESET' Trans_MP-E4 R428-1 J3-48 NET 'MP_Trans_3V3' R425-2 R426-2 R427-2 R428-2 # # Transmitter MiniPOD Power Supply Nets # NET 'MP_Trans_3V3' Trans_MP-C4 Trans_MP-C5 Trans_MP-C6 NET 'MP_Trans_2V5' Trans_MP-F4 NET 'MP_Trans_2V5' Trans_MP-G4 Trans_MP-G5 Trans_MP-G6 # # Transmitter MiniPOD 2.5 Volt Power Filter NET 'BULK_2V5' L411-1 C411-1 C412-2 C413-1 NET 'GROUND' C411-2 C412-1 C413-2 NET 'MP_Trans_2V5' L411-2 C414-2 C415-1 C416-1 NET 'GROUND' C414-1 C415-2 R411-1 NET 'MP_Trans_2V5_FLT_RES' C416-2 R411-2 # # Transmitter MiniPOD 3.3 Volt Power Filter NET 'BULK_3V3' L421-1 C421-1 C422-2 C423-1 NET 'GROUND' C421-2 C422-1 C423-2 NET 'MP_Trans_3V3' L421-2 C424-2 C425-1 C426-1 NET 'GROUND' C424-1 C425-2 R421-1 NET 'MP_Trans_3V3_FLT_RES' C426-2 R421-2 # # Now the Do Not Connect Pins # on the Transmitter MiniPOD # NET 'No_Conn_Trans_MP_C7' Trans_MP-C7 NET 'No_Conn_Trans_MP_D5' Trans_MP-D5 NET 'No_Conn_Trans_MP_E5' Trans_MP-E5 NET 'No_Conn_Trans_MP_E7' Trans_MP-E7 NET 'No_Conn_Trans_MP_F5' Trans_MP-F5 NET 'No_Conn_Trans_MP_F6' Trans_MP-F6 NET 'No_Conn_Trans_MP_G7' Trans_MP-G7 # # We are only using 4 of the 12 Channels/Fibers # in the Transmitter MiniPOD because we only # have 4 MGT Transmitters available to drive the # Transmitter MiniPOD. # # The 4 Fibers that we are using are # MiniPOD Fiber numbers: 0, 1, 2, 3 # # The Data Input pins for the other 8 Fibers are # not connected in the HTM design and thus need to # be "No_Conn" pins in the HTM NetList. # NET 'No_Conn_Trans_MP_A4' Trans_MP-A4 NET 'No_Conn_Trans_MP_B4' Trans_MP-B4 NET 'No_Conn_Trans_MP_H4' Trans_MP-H4 NET 'No_Conn_Trans_MP_J4' Trans_MP-J4 NET 'No_Conn_Trans_MP_A6' Trans_MP-A6 NET 'No_Conn_Trans_MP_B6' Trans_MP-B6 NET 'No_Conn_Trans_MP_H6' Trans_MP-H6 NET 'No_Conn_Trans_MP_J6' Trans_MP-J6 NET 'No_Conn_Trans_MP_A8' Trans_MP-A8 NET 'No_Conn_Trans_MP_B8' Trans_MP-B8 NET 'No_Conn_Trans_MP_H8' Trans_MP-H8 NET 'No_Conn_Trans_MP_J8' Trans_MP-J8 NET 'No_Conn_Trans_MP_D8' Trans_MP-D8 NET 'No_Conn_Trans_MP_D9' Trans_MP-D9 NET 'No_Conn_Trans_MP_F8' Trans_MP-F8 NET 'No_Conn_Trans_MP_F9' Trans_MP-F9