# # BULK_2V5 Supply # # HTM Net List File # --------------------- # # # Original Rev. 26-Feb-2018 # Current Rev. 5-Apr-2018 # # # # This file holds all of the nets for the # BULK_2V5 supply. # # This is a 3 Amps. # # This HTM card supply uses a LT1764A linear # regulator for this supply. # # # Connect the regulator's V_Input, V_Output, and Ground terminals: # NET 'FLTR_12V_INPUT_TWO' U111-2 NET 'BULK_2V5' U111-4 NET 'GROUND' U111-3 # # Connect the regulator's 35 Thermal Pad Vias + 4 Heatsink Vias # NET 'GROUND' U111-6 U111-7 U111-8 U111-9 U111-10 NET 'GROUND' U111-11 U111-12 U111-13 U111-14 U111-15 NET 'GROUND' U111-16 U111-17 U111-18 U111-19 U111-20 NET 'GROUND' U111-21 U111-22 U111-23 U111-24 U111-25 NET 'GROUND' U111-26 U111-27 U111-28 U111-29 U111-30 NET 'GROUND' U111-31 U111-32 U111-33 U111-34 U111-35 NET 'GROUND' U111-36 U111-37 U111-38 U111-39 U111-40 NET 'GROUND' U111-41 U111-42 U111-43 U111-44 # # Connect this regulator's Input Filter: # NET 'FLTR_12V_INPUT_TWO' C111-2 C112-2 C116-1 C117-1 NET 'GROUND' C111-1 C112-1 C116-2 C117-2 # # Connect this regulator's Output Filter: # NET 'BULK_2V5' C114-1 C115-1 DZ111-1 NET 'GROUND' C114-2 C115-2 DZ111-2 # # Connect this regulator's SHUT_DOWN_B terminal: # NET 'BULK_2V5_SHDN_B' U111-1 R111-2 NET 'FLTR_12V_INPUT_TWO' R111-1 # # Connect this regulator's SENSE_ADJUST terminal: # NET 'BULK_2V5_ADJUST' U111-5 R113-2 C113-1 NET 'BULK_2V5' R112-2 NET 'BULK_2V5_TRM_TOP' R112-1 R113-1 C113-2 NET 'BULK_2V5_TRM_BOT' R114-1 R113-3 NET 'GROUND' R114-2 # # Input Filter for Voltage Drop and High Frequency Noise # NET 'ISO_12V' R115-1 C110-2 NET 'FLTR_Step_1_TWO' R115-2 R116-1 NET 'FLTR_Step_2_TWO' R116-2 L111-1 NET 'FLTR_12V_INPUT_TWO' L111-2 NET 'GROUND' C110-1