---------------------------------------------------------------------- Collection of eye diagram for rx: hub2.Q127.ch0/hub2.GT.ch52 ---------------------------------------------------------------------- [May 9 17:33:05 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 52 Value after writing: 52 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 17:33:27 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 17:33:39 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 17:33:52 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 17:34:04 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 17:34:17 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 17:34:30 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [May 9 17:34:32 2021]: Finished collection process. Required 6 realignments. Open Area: 48.2% (15776) Horizontal Opening: 60.6% (80) Vertical Opening: 91.9% (228) ---------------------------------------------------------------------- Collection of eye diagram for rx: hub2.Q127.ch0/hub2.GT.ch52 ---------------------------------------------------------------------- [May 10 08:17:22 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 52 Value after writing: 52 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [May 10 08:17:33 2021]: Finished collection process. Required 0 realignments. Open Area: 48.2% (15776) Horizontal Opening: 60.6% (80) Vertical Opening: 91.9% (228)