---------------------------------------------------------------------- Collection of eye diagram for rx: hub2.Q130.ch3/hub2.GT.ch67 ---------------------------------------------------------------------- [May 9 18:04:06 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 67 Value after writing: 67 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:04:28 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:04:41 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:04:54 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:05:06 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [May 9 18:05:08 2021]: Finished collection process. Required 4 realignments. Open Area: 49.4% (16176) Horizontal Opening: 63.6% (84) Vertical Opening: 91.9% (228) ---------------------------------------------------------------------- Collection of eye diagram for rx: hub2.Q130.ch3/hub2.GT.ch67 ---------------------------------------------------------------------- [May 10 08:28:24 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 67 Value after writing: 67 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [May 10 08:28:35 2021]: Finished collection process. Required 0 realignments. Open Area: 49.6% (16240) Horizontal Opening: 63.6% (84) Vertical Opening: 93.5% (232)