---------------------------------------------------------------------- Collection of eye diagram for rx: hub2.Q131.ch2/hub2.GT.ch70 ---------------------------------------------------------------------- [May 9 18:06:52 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 70 Value after writing: 70 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:07:14 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:07:26 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:07:39 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:07:52 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:08:04 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 18:08:17 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [May 9 18:08:19 2021]: Finished collection process. Required 6 realignments. Open Area: 46.3% (15152) Horizontal Opening: 60.6% (80) Vertical Opening: 88.7% (220) ---------------------------------------------------------------------- Collection of eye diagram for rx: hub2.Q131.ch2/hub2.GT.ch70 ---------------------------------------------------------------------- [May 10 08:29:28 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 70 Value after writing: 70 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [May 10 08:29:39 2021]: Finished collection process. Required 0 realignments. Open Area: 46.5% (15216) Horizontal Opening: 60.6% (80) Vertical Opening: 90.3% (224)