---------------------------------------------------------------------- Collection of eye diagram for rx: hub1.Q232.ch2/hub1.GT.ch34 ---------------------------------------------------------------------- [May 31 14:00:12 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 34 Value after writing: 34 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Timeout of 10.00 seconds reached waiting for eye data ready. Lowering eye_go, then performing realignment. Lowering eye_go Value of eye_go after lowering: 0 Performing realignment. [May 31 14:00:34 2021]: Realignment finished. Reattempting collection process. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [May 31 14:00:45 2021]: Finished collection process. Required 1 realignments. Open Area: 46.8% (15328) Horizontal Opening: 54.5% (72) Vertical Opening: 100.0% (248)