---------------------------------------------------------------------- Collection of eye diagram for rx: hub1.Q130.ch3/hub1.GT.ch67 ---------------------------------------------------------------------- [Jun 13 18:54:30 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 67 Value after writing: 67 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Lowering eye_go, then performing realignment. Lowering eye_go Value of eye_go after lowering: 0 Performing realignment. [Jun 13 18:54:43 2021]: Realignment finished. Reattempting collection process. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [Jun 13 18:54:54 2021]: Finished collection process. Required 1 realignments. Open Area: 53.0% (17360) Horizontal Opening: 66.7% (88) Vertical Opening: 96.8% (240)