---------------------------------------------------------------------- Collection of eye diagram for rx: hub1.Q128.ch0/hub1.GT.ch56 ---------------------------------------------------------------------- [May 9 17:06:07 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 56 Value after writing: 56 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 17:06:29 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 17:06:42 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Realignment required. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Performing realignment. [May 9 17:06:55 2021]: Realignment finished. Reattempting collection process. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... [May 9 17:07:05 2021]: Due to runtime error (RuntimeError('Eye data not ready after 10 seconds. Exiting program ...\n',)), eye diagram could not be collected. [May 9 17:07:05 2021]: Exception occured: ValueError('No eye data recoverd (drp addr never 0x251)',) Eye diagram collection may have failed ---------------------------------------------------------------------- Collection of eye diagram for rx: hub1.Q128.ch0/hub1.GT.ch56 ---------------------------------------------------------------------- [May 10 08:02:56 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 56 Value after writing: 56 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... [May 10 08:03:15 2021]: Due to runtime error (RuntimeError('Eye data not ready after 10 seconds. Exiting program ...\n',)), eye diagram could not be collected. [May 10 08:03:15 2021]: Exception occured: ValueError('No eye data recoverd (drp addr never 0x251)',) Eye diagram collection may have failed