---------------------------------------------------------------------- Collection of eye diagram for rx: hub1.Q133.ch1/hub1.GT.ch77 ---------------------------------------------------------------------- [May 13 00:10:43 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 77 Value after writing: 77 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [May 13 00:10:54 2021]: Finished collection process. Required 0 realignments. Open Area: 54.0% (17680) Horizontal Opening: 63.6% (84) Vertical Opening: 96.8% (240)