---------------------------------------------------------------------- Collection of eye diagram for rx: rod1.Q113.ch1/rod1.GT.ch53 ---------------------------------------------------------------------- [Apr 28 17:16:21 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 53 Value after writing: 53 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [Apr 28 17:16:32 2021]: Finished collection process. Required 0 realignments. Open Area: 56.2% (9472) Horizontal Opening: 70.6% (48) Vertical Opening: 100.0% (248)