---------------------------------------------------------------------- Collection of eye diagram for rx: rod1.Q216.ch3/rod1.GT.ch27 ---------------------------------------------------------------------- [Apr 26 12:43:17 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 27 Value after writing: 27 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [Apr 26 12:43:28 2021]: Finished collection process. Required 0 realignments. Open Area: 47.7% (8048) Horizontal Opening: 58.8% (40) Vertical Opening: 90.3% (224)