---------------------------------------------------------------------- Collection of eye diagram for rx: htm7.Q111.ch3/htm7.GT.ch11 ---------------------------------------------------------------------- [Apr 23 01:25:59 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 11 Value after writing: 11 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in less than 1.50 seconds. Lowering eye_go, then performing realignment. Lowering eye_go Value of eye_go after lowering: 0 Performing realignment. [Apr 23 01:26:11 2021]: Realignment finished. Reattempting collection process. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [Apr 23 01:26:23 2021]: Finished collection process. Required 1 realignments. Open Area: 31.4% (5296) Horizontal Opening: 64.7% (44) Vertical Opening: 82.3% (204)