---------------------------------------------------------------------- Collection of eye diagram for rx: rod2.Q119.ch3/rod2.GT.ch79 ---------------------------------------------------------------------- [Apr 22 23:42:10 2021]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 79 Value after writing: 79 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 10.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [Apr 22 23:42:22 2021]: Finished collection process. Required 0 realignments. Open Area: 42.7% (7200) Horizontal Opening: 58.8% (40) Vertical Opening: 90.3% (224)