---------------------------------------------------------------------- Collection of eye diagram for rx: hub1.Q133.ch1/hub1.GT.ch77 ---------------------------------------------------------------------- [Oct 5 09:58:24 2022]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 77 Value after writing: 77 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 3.00 seconds) ... Eye data ready in less than 1.50 seconds. Lowering eye_go, then performing realignment. Lowering eye_go Value of eye_go after lowering: 0 Performing realignment. [Oct 5 09:58:41 2022]: Realignment finished. Reattempting collection process. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 3.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [Oct 5 09:58:52 2022]: Finished collection process. Required 1 realignments. Open Area: 46.8% (15312) Horizontal Opening: 57.6% (76) Vertical Opening: 93.5% (232)