# MIGT>---------------------------------------------- # MIGT> V1.0 -- Wed Feb 15 13:01:29 2017 # MIGT> begin substituting from -- instance #1/3 # MIGT>---------------------------------------------- # # Front Ethernet TRC Components Template File # # for Etherent Transformer #1 # ---- # # # Original Rev. 6-Apr-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRC Components for 2 complete # 10/100/1000 Base-T Ethernet connections that are # services by Ethernet "Transformer" number 1. # # - First place the Ethernet Transformer #1 itself. # # - Then the 4 capacitors are the Phys side center tap bypass caps. # # - Then the 4 resistors are the Cable side center tap Bob Smith Termination. # # - Then the 1 nFd capacitor ties the Bob Smith Termination to ground. # # - First there are all 9 components for one Ethernet connection # and then the 9 components for the other Ethernet connection # that is serviced by this Ethernet "Transformer". # # The contents of this file will be shifted by Delta_X Delta_Y # before they are actually placed in the design. # # This file holds the RC Components for # Etherent "Transformer" Number: 1 # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS1 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 36.000000 124.000000 1 90 C1401 Cap_100_nFd_0603 SY_JUNK cap_0603 43.000000 132.000000 2 270 C1402 Cap_100_nFd_0603 SY_JUNK cap_0603 41.300000 132.000000 2 270 C1403 Cap_100_nFd_0603 SY_JUNK cap_0603 39.500000 132.000000 2 270 C1404 Cap_100_nFd_0603 SY_JUNK cap_0603 37.800000 132.000000 2 270 R1401 Res_49R9_Ohm_0603 SY_JUNK res_0603 34.200000 132.000000 2 90 R1402 Res_49R9_Ohm_0603 SY_JUNK res_0603 32.500000 132.000000 2 90 R1403 Res_49R9_Ohm_0603 SY_JUNK res_0603 30.700000 132.000000 2 90 R1404 Res_49R9_Ohm_0603 SY_JUNK res_0603 29.000000 132.000000 2 90 C1405 Cap_1_nFd_0603 SY_JUNK cap_0603 36.000000 132.000000 2 270 C1406 Cap_100_nFd_0603 SY_JUNK cap_0603 43.000000 116.000000 2 90 C1407 Cap_100_nFd_0603 SY_JUNK cap_0603 41.300000 116.000000 2 90 C1408 Cap_100_nFd_0603 SY_JUNK cap_0603 39.500000 116.000000 2 90 C1409 Cap_100_nFd_0603 SY_JUNK cap_0603 37.800000 116.000000 2 90 R1406 Res_49R9_Ohm_0603 SY_JUNK res_0603 34.200000 116.000000 2 270 R1407 Res_49R9_Ohm_0603 SY_JUNK res_0603 32.500000 116.000000 2 270 R1408 Res_49R9_Ohm_0603 SY_JUNK res_0603 30.700000 116.000000 2 270 R1409 Res_49R9_Ohm_0603 SY_JUNK res_0603 29.000000 116.000000 2 270 C1410 Cap_1_nFd_0603 SY_JUNK cap_0603 36.000000 116.000000 2 90 # MIGT>---------------------------------------------- # MIGT> done substituting from # MIGT>---------------------------------------------- # MIGT> V1.0 -- Wed Feb 15 13:01:29 2017 # MIGT> begin substituting from -- instance #2/3 # MIGT>---------------------------------------------- # # Front Ethernet TRC Components Template File # # for Etherent Transformer #2 # ---- # # # Original Rev. 6-Apr-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRC Components for 2 complete # 10/100/1000 Base-T Ethernet connections that are # services by Ethernet "Transformer" number 2. # # - First place the Ethernet Transformer #2 itself. # # - Then the 4 capacitors are the Phys side center tap bypass caps. # # - Then the 4 resistors are the Cable side center tap Bob Smith Termination. # # - Then the 1 nFd capacitor ties the Bob Smith Termination to ground. # # - First there are all 9 components for one Ethernet connection # and then the 9 components for the other Ethernet connection # that is serviced by this Ethernet "Transformer". # # The contents of this file will be shifted by Delta_X Delta_Y # before they are actually placed in the design. # # This file holds the RC Components for # Etherent "Transformer" Number: 2 # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS2 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 36.000000 102.000000 1 90 C1411 Cap_100_nFd_0603 SY_JUNK cap_0603 43.000000 110.000000 2 270 C1412 Cap_100_nFd_0603 SY_JUNK cap_0603 41.300000 110.000000 2 270 C1413 Cap_100_nFd_0603 SY_JUNK cap_0603 39.500000 110.000000 2 270 C1414 Cap_100_nFd_0603 SY_JUNK cap_0603 37.800000 110.000000 2 270 R1411 Res_49R9_Ohm_0603 SY_JUNK res_0603 34.200000 110.000000 2 90 R1412 Res_49R9_Ohm_0603 SY_JUNK res_0603 32.500000 110.000000 2 90 R1413 Res_49R9_Ohm_0603 SY_JUNK res_0603 30.700000 110.000000 2 90 R1414 Res_49R9_Ohm_0603 SY_JUNK res_0603 29.000000 110.000000 2 90 C1415 Cap_1_nFd_0603 SY_JUNK cap_0603 36.000000 110.000000 2 270 C1416 Cap_100_nFd_0603 SY_JUNK cap_0603 43.000000 94.000000 2 90 C1417 Cap_100_nFd_0603 SY_JUNK cap_0603 41.300000 94.000000 2 90 C1418 Cap_100_nFd_0603 SY_JUNK cap_0603 39.500000 94.000000 2 90 C1419 Cap_100_nFd_0603 SY_JUNK cap_0603 37.800000 94.000000 2 90 R1416 Res_49R9_Ohm_0603 SY_JUNK res_0603 34.200000 94.000000 2 270 R1417 Res_49R9_Ohm_0603 SY_JUNK res_0603 32.500000 94.000000 2 270 R1418 Res_49R9_Ohm_0603 SY_JUNK res_0603 30.700000 94.000000 2 270 R1419 Res_49R9_Ohm_0603 SY_JUNK res_0603 29.000000 94.000000 2 270 C1420 Cap_1_nFd_0603 SY_JUNK cap_0603 36.000000 94.000000 2 90 # MIGT>---------------------------------------------- # MIGT> done substituting from # MIGT>---------------------------------------------- # MIGT> V1.0 -- Wed Feb 15 13:01:29 2017 # MIGT> begin substituting from -- instance #3/3 # MIGT>---------------------------------------------- # # Front Ethernet TRC Components Template File # # for Etherent Transformer #3 # ---- # # # Original Rev. 6-Apr-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRC Components for 2 complete # 10/100/1000 Base-T Ethernet connections that are # services by Ethernet "Transformer" number 3. # # - First place the Ethernet Transformer #3 itself. # # - Then the 4 capacitors are the Phys side center tap bypass caps. # # - Then the 4 resistors are the Cable side center tap Bob Smith Termination. # # - Then the 1 nFd capacitor ties the Bob Smith Termination to ground. # # - First there are all 9 components for one Ethernet connection # and then the 9 components for the other Ethernet connection # that is serviced by this Ethernet "Transformer". # # The contents of this file will be shifted by Delta_X Delta_Y # before they are actually placed in the design. # # This file holds the RC Components for # Etherent "Transformer" Number: 3 # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS3 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 36.000000 80.000000 1 90 C1421 Cap_100_nFd_0603 SY_JUNK cap_0603 43.000000 88.000000 2 270 C1422 Cap_100_nFd_0603 SY_JUNK cap_0603 41.300000 88.000000 2 270 C1423 Cap_100_nFd_0603 SY_JUNK cap_0603 39.500000 88.000000 2 270 C1424 Cap_100_nFd_0603 SY_JUNK cap_0603 37.800000 88.000000 2 270 R1421 Res_49R9_Ohm_0603 SY_JUNK res_0603 34.200000 88.000000 2 90 R1422 Res_49R9_Ohm_0603 SY_JUNK res_0603 32.500000 88.000000 2 90 R1423 Res_49R9_Ohm_0603 SY_JUNK res_0603 30.700000 88.000000 2 90 R1424 Res_49R9_Ohm_0603 SY_JUNK res_0603 29.000000 88.000000 2 90 C1425 Cap_1_nFd_0603 SY_JUNK cap_0603 36.000000 88.000000 2 270 C1426 Cap_100_nFd_0603 SY_JUNK cap_0603 43.000000 72.000000 2 90 C1427 Cap_100_nFd_0603 SY_JUNK cap_0603 41.300000 72.000000 2 90 C1428 Cap_100_nFd_0603 SY_JUNK cap_0603 39.500000 72.000000 2 90 C1429 Cap_100_nFd_0603 SY_JUNK cap_0603 37.800000 72.000000 2 90 R1426 Res_49R9_Ohm_0603 SY_JUNK res_0603 34.200000 72.000000 2 270 R1427 Res_49R9_Ohm_0603 SY_JUNK res_0603 32.500000 72.000000 2 270 R1428 Res_49R9_Ohm_0603 SY_JUNK res_0603 30.700000 72.000000 2 270 R1429 Res_49R9_Ohm_0603 SY_JUNK res_0603 29.000000 72.000000 2 270 C1430 Cap_1_nFd_0603 SY_JUNK cap_0603 36.000000 72.000000 2 90 # MIGT>---------------------------------------------- # MIGT> done substituting from # # Ethernet TRNS4 Magnetics and RC Comps # # Hub Module Key In Components File # -------------------------------------- # # # Original Rev. 1-May-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRNS4 Ethernet Magnetics and # its associated RC Components. # # These are located on the buldge to the East near # top of the Hub-Module. # # TRNS4 is the Ethernet Magnetics for the 2 links # that run between the 2 Hub Modules in a shelf. # # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS4 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 267.000000 203.500000 1 180 C1431 Cap_100_nFd_0603 SY_JUNK cap_0603 259.000000 210.500000 2 0 C1432 Cap_100_nFd_0603 SY_JUNK cap_0603 259.000000 208.800000 2 0 C1433 Cap_100_nFd_0603 SY_JUNK cap_0603 259.000000 207.000000 2 0 C1434 Cap_100_nFd_0603 SY_JUNK cap_0603 259.000000 205.300000 2 0 R1431 Res_49R9_Ohm_0603 SY_JUNK res_0603 259.000000 201.700000 2 180 R1432 Res_49R9_Ohm_0603 SY_JUNK res_0603 259.000000 200.000000 2 180 R1433 Res_49R9_Ohm_0603 SY_JUNK res_0603 259.000000 198.200000 2 180 R1434 Res_49R9_Ohm_0603 SY_JUNK res_0603 259.000000 196.500000 2 180 C1435 Cap_1_nFd_0603 SY_JUNK cap_0603 259.000000 203.500000 2 0 C1436 Cap_100_nFd_0603 SY_JUNK cap_0603 275.000000 210.500000 2 180 C1437 Cap_100_nFd_0603 SY_JUNK cap_0603 275.000000 208.800000 2 180 C1438 Cap_100_nFd_0603 SY_JUNK cap_0603 275.000000 207.000000 2 180 C1439 Cap_100_nFd_0603 SY_JUNK cap_0603 275.000000 205.300000 2 180 R1436 Res_49R9_Ohm_0603 SY_JUNK res_0603 275.000000 201.700000 2 0 R1437 Res_49R9_Ohm_0603 SY_JUNK res_0603 275.000000 200.000000 2 0 R1438 Res_49R9_Ohm_0603 SY_JUNK res_0603 275.000000 198.200000 2 0 R1439 Res_49R9_Ohm_0603 SY_JUNK res_0603 275.000000 196.500000 2 0 C1440 Cap_1_nFd_0603 SY_JUNK cap_0603 275.000000 203.500000 2 180 # MIGT>---------------------------------------------- # MIGT> V1.0 -- Wed Feb 15 13:01:31 2017 # MIGT> begin substituting from -- instance #2/7 # MIGT>---------------------------------------------- # # Rear Ethernet TRC Components Template File # # for Etherent Transformer #5 # ---- # # # Original Rev. 23-Apr-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRC Components for 2 complete # 10/100/1000 Base-T Ethernet connections that are # services by Ethernet "Transformer" number 5. # # - First place the Ethernet Transformer #5 itself. # # - Then the 4 capacitors are the Phys side center tap bypass caps. # # - Then the 4 resistors are the Cable side center tap Bob Smith Termination. # # - Then the 1 nFd capacitor ties the Bob Smith Termination to ground. # # - First there are all 9 components for one Ethernet connection # and then the 9 components for the other Ethernet connection # that is serviced by this Ethernet "Transformer". # # The contents of this file will be shifted by Delta_X Delta_Y # before they are actually placed in the design. # # This file holds the RC Components for # Etherent "Transformer" Number: 5 # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS5 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 204.000000 59.500000 1 270 C1441 Cap_100_nFd_0603 SY_JUNK cap_0603 197.000000 51.500000 2 270 C1442 Cap_100_nFd_0603 SY_JUNK cap_0603 198.700000 51.500000 2 270 C1443 Cap_100_nFd_0603 SY_JUNK cap_0603 200.500000 51.500000 2 270 C1444 Cap_100_nFd_0603 SY_JUNK cap_0603 202.200000 51.500000 2 270 R1441 Res_49R9_Ohm_0603 SY_JUNK res_0603 205.800000 51.500000 2 90 R1442 Res_49R9_Ohm_0603 SY_JUNK res_0603 207.500000 51.500000 2 90 R1443 Res_49R9_Ohm_0603 SY_JUNK res_0603 209.300000 51.500000 2 90 R1444 Res_49R9_Ohm_0603 SY_JUNK res_0603 211.000000 51.500000 2 90 C1445 Cap_1_nFd_0603 SY_JUNK cap_0603 204.000000 51.500000 2 270 C1446 Cap_100_nFd_0603 SY_JUNK cap_0603 197.000000 67.500000 2 90 C1447 Cap_100_nFd_0603 SY_JUNK cap_0603 198.700000 67.500000 2 90 C1448 Cap_100_nFd_0603 SY_JUNK cap_0603 200.500000 67.500000 2 90 C1449 Cap_100_nFd_0603 SY_JUNK cap_0603 202.200000 67.500000 2 90 R1446 Res_49R9_Ohm_0603 SY_JUNK res_0603 205.800000 67.500000 2 270 R1447 Res_49R9_Ohm_0603 SY_JUNK res_0603 207.500000 67.500000 2 270 R1448 Res_49R9_Ohm_0603 SY_JUNK res_0603 209.300000 67.500000 2 270 R1449 Res_49R9_Ohm_0603 SY_JUNK res_0603 211.000000 67.500000 2 270 C1450 Cap_1_nFd_0603 SY_JUNK cap_0603 204.000000 67.500000 2 90 # MIGT>---------------------------------------------- # MIGT> done substituting from # MIGT>---------------------------------------------- # MIGT> V1.0 -- Wed Feb 15 13:01:31 2017 # MIGT> begin substituting from -- instance #3/7 # MIGT>---------------------------------------------- # # Rear Ethernet TRC Components Template File # # for Etherent Transformer #6 # ---- # # # Original Rev. 23-Apr-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRC Components for 2 complete # 10/100/1000 Base-T Ethernet connections that are # services by Ethernet "Transformer" number 6. # # - First place the Ethernet Transformer #6 itself. # # - Then the 4 capacitors are the Phys side center tap bypass caps. # # - Then the 4 resistors are the Cable side center tap Bob Smith Termination. # # - Then the 1 nFd capacitor ties the Bob Smith Termination to ground. # # - First there are all 9 components for one Ethernet connection # and then the 9 components for the other Ethernet connection # that is serviced by this Ethernet "Transformer". # # The contents of this file will be shifted by Delta_X Delta_Y # before they are actually placed in the design. # # This file holds the RC Components for # Etherent "Transformer" Number: 6 # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS6 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 224.000000 59.500000 1 270 C1451 Cap_100_nFd_0603 SY_JUNK cap_0603 217.000000 51.500000 2 270 C1452 Cap_100_nFd_0603 SY_JUNK cap_0603 218.700000 51.500000 2 270 C1453 Cap_100_nFd_0603 SY_JUNK cap_0603 220.500000 51.500000 2 270 C1454 Cap_100_nFd_0603 SY_JUNK cap_0603 222.200000 51.500000 2 270 R1451 Res_49R9_Ohm_0603 SY_JUNK res_0603 225.800000 51.500000 2 90 R1452 Res_49R9_Ohm_0603 SY_JUNK res_0603 227.500000 51.500000 2 90 R1453 Res_49R9_Ohm_0603 SY_JUNK res_0603 229.300000 51.500000 2 90 R1454 Res_49R9_Ohm_0603 SY_JUNK res_0603 231.000000 51.500000 2 90 C1455 Cap_1_nFd_0603 SY_JUNK cap_0603 224.000000 51.500000 2 270 C1456 Cap_100_nFd_0603 SY_JUNK cap_0603 217.000000 67.500000 2 90 C1457 Cap_100_nFd_0603 SY_JUNK cap_0603 218.700000 67.500000 2 90 C1458 Cap_100_nFd_0603 SY_JUNK cap_0603 220.500000 67.500000 2 90 C1459 Cap_100_nFd_0603 SY_JUNK cap_0603 222.200000 67.500000 2 90 R1456 Res_49R9_Ohm_0603 SY_JUNK res_0603 225.800000 67.500000 2 270 R1457 Res_49R9_Ohm_0603 SY_JUNK res_0603 227.500000 67.500000 2 270 R1458 Res_49R9_Ohm_0603 SY_JUNK res_0603 229.300000 67.500000 2 270 R1459 Res_49R9_Ohm_0603 SY_JUNK res_0603 231.000000 67.500000 2 270 C1460 Cap_1_nFd_0603 SY_JUNK cap_0603 224.000000 67.500000 2 90 # MIGT>---------------------------------------------- # MIGT> done substituting from # MIGT>---------------------------------------------- # MIGT> V1.0 -- Wed Feb 15 13:01:31 2017 # MIGT> begin substituting from -- instance #4/7 # MIGT>---------------------------------------------- # # Rear Ethernet TRC Components Template File # # for Etherent Transformer #7 # ---- # # # Original Rev. 23-Apr-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRC Components for 2 complete # 10/100/1000 Base-T Ethernet connections that are # services by Ethernet "Transformer" number 7. # # - First place the Ethernet Transformer #7 itself. # # - Then the 4 capacitors are the Phys side center tap bypass caps. # # - Then the 4 resistors are the Cable side center tap Bob Smith Termination. # # - Then the 1 nFd capacitor ties the Bob Smith Termination to ground. # # - First there are all 9 components for one Ethernet connection # and then the 9 components for the other Ethernet connection # that is serviced by this Ethernet "Transformer". # # The contents of this file will be shifted by Delta_X Delta_Y # before they are actually placed in the design. # # This file holds the RC Components for # Etherent "Transformer" Number: 7 # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS7 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 244.000000 59.500000 1 270 C1461 Cap_100_nFd_0603 SY_JUNK cap_0603 237.000000 51.500000 2 270 C1462 Cap_100_nFd_0603 SY_JUNK cap_0603 238.700000 51.500000 2 270 C1463 Cap_100_nFd_0603 SY_JUNK cap_0603 240.500000 51.500000 2 270 C1464 Cap_100_nFd_0603 SY_JUNK cap_0603 242.200000 51.500000 2 270 R1461 Res_49R9_Ohm_0603 SY_JUNK res_0603 245.800000 51.500000 2 90 R1462 Res_49R9_Ohm_0603 SY_JUNK res_0603 247.500000 51.500000 2 90 R1463 Res_49R9_Ohm_0603 SY_JUNK res_0603 249.300000 51.500000 2 90 R1464 Res_49R9_Ohm_0603 SY_JUNK res_0603 251.000000 51.500000 2 90 C1465 Cap_1_nFd_0603 SY_JUNK cap_0603 244.000000 51.500000 2 270 C1466 Cap_100_nFd_0603 SY_JUNK cap_0603 237.000000 67.500000 2 90 C1467 Cap_100_nFd_0603 SY_JUNK cap_0603 238.700000 67.500000 2 90 C1468 Cap_100_nFd_0603 SY_JUNK cap_0603 240.500000 67.500000 2 90 C1469 Cap_100_nFd_0603 SY_JUNK cap_0603 242.200000 67.500000 2 90 R1466 Res_49R9_Ohm_0603 SY_JUNK res_0603 245.800000 67.500000 2 270 R1467 Res_49R9_Ohm_0603 SY_JUNK res_0603 247.500000 67.500000 2 270 R1468 Res_49R9_Ohm_0603 SY_JUNK res_0603 249.300000 67.500000 2 270 R1469 Res_49R9_Ohm_0603 SY_JUNK res_0603 251.000000 67.500000 2 270 C1470 Cap_1_nFd_0603 SY_JUNK cap_0603 244.000000 67.500000 2 90 # MIGT>---------------------------------------------- # MIGT> done substituting from # MIGT>---------------------------------------------- # MIGT> V1.0 -- Wed Feb 15 13:01:31 2017 # MIGT> begin substituting from -- instance #5/7 # MIGT>---------------------------------------------- # # Rear Ethernet TRC Components Template File # # for Etherent Transformer #8 # ---- # # # Original Rev. 23-Apr-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRC Components for 2 complete # 10/100/1000 Base-T Ethernet connections that are # services by Ethernet "Transformer" number 8. # # - First place the Ethernet Transformer #8 itself. # # - Then the 4 capacitors are the Phys side center tap bypass caps. # # - Then the 4 resistors are the Cable side center tap Bob Smith Termination. # # - Then the 1 nFd capacitor ties the Bob Smith Termination to ground. # # - First there are all 9 components for one Ethernet connection # and then the 9 components for the other Ethernet connection # that is serviced by this Ethernet "Transformer". # # The contents of this file will be shifted by Delta_X Delta_Y # before they are actually placed in the design. # # This file holds the RC Components for # Etherent "Transformer" Number: 8 # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS8 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 194.000000 35.500000 1 270 C1471 Cap_100_nFd_0603 SY_JUNK cap_0603 187.000000 27.500000 2 270 C1472 Cap_100_nFd_0603 SY_JUNK cap_0603 188.700000 27.500000 2 270 C1473 Cap_100_nFd_0603 SY_JUNK cap_0603 190.500000 27.500000 2 270 C1474 Cap_100_nFd_0603 SY_JUNK cap_0603 192.200000 27.500000 2 270 R1471 Res_49R9_Ohm_0603 SY_JUNK res_0603 195.800000 27.500000 2 90 R1472 Res_49R9_Ohm_0603 SY_JUNK res_0603 197.500000 27.500000 2 90 R1473 Res_49R9_Ohm_0603 SY_JUNK res_0603 199.300000 27.500000 2 90 R1474 Res_49R9_Ohm_0603 SY_JUNK res_0603 201.000000 27.500000 2 90 C1475 Cap_1_nFd_0603 SY_JUNK cap_0603 194.000000 27.500000 2 270 C1476 Cap_100_nFd_0603 SY_JUNK cap_0603 187.000000 43.500000 2 90 C1477 Cap_100_nFd_0603 SY_JUNK cap_0603 188.700000 43.500000 2 90 C1478 Cap_100_nFd_0603 SY_JUNK cap_0603 190.500000 43.500000 2 90 C1479 Cap_100_nFd_0603 SY_JUNK cap_0603 192.200000 43.500000 2 90 R1476 Res_49R9_Ohm_0603 SY_JUNK res_0603 195.800000 43.500000 2 270 R1477 Res_49R9_Ohm_0603 SY_JUNK res_0603 197.500000 43.500000 2 270 R1478 Res_49R9_Ohm_0603 SY_JUNK res_0603 199.300000 43.500000 2 270 R1479 Res_49R9_Ohm_0603 SY_JUNK res_0603 201.000000 43.500000 2 270 C1480 Cap_1_nFd_0603 SY_JUNK cap_0603 194.000000 43.500000 2 90 # MIGT>---------------------------------------------- # MIGT> done substituting from # MIGT>---------------------------------------------- # MIGT> V1.0 -- Wed Feb 15 13:01:31 2017 # MIGT> begin substituting from -- instance #6/7 # MIGT>---------------------------------------------- # # Rear Ethernet TRC Components Template File # # for Etherent Transformer #9 # ---- # # # Original Rev. 23-Apr-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRC Components for 2 complete # 10/100/1000 Base-T Ethernet connections that are # services by Ethernet "Transformer" number 9. # # - First place the Ethernet Transformer #9 itself. # # - Then the 4 capacitors are the Phys side center tap bypass caps. # # - Then the 4 resistors are the Cable side center tap Bob Smith Termination. # # - Then the 1 nFd capacitor ties the Bob Smith Termination to ground. # # - First there are all 9 components for one Ethernet connection # and then the 9 components for the other Ethernet connection # that is serviced by this Ethernet "Transformer". # # The contents of this file will be shifted by Delta_X Delta_Y # before they are actually placed in the design. # # This file holds the RC Components for # Etherent "Transformer" Number: 9 # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS9 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 214.000000 35.500000 1 270 C1481 Cap_100_nFd_0603 SY_JUNK cap_0603 207.000000 27.500000 2 270 C1482 Cap_100_nFd_0603 SY_JUNK cap_0603 208.700000 27.500000 2 270 C1483 Cap_100_nFd_0603 SY_JUNK cap_0603 210.500000 27.500000 2 270 C1484 Cap_100_nFd_0603 SY_JUNK cap_0603 212.200000 27.500000 2 270 R1481 Res_49R9_Ohm_0603 SY_JUNK res_0603 215.800000 27.500000 2 90 R1482 Res_49R9_Ohm_0603 SY_JUNK res_0603 217.500000 27.500000 2 90 R1483 Res_49R9_Ohm_0603 SY_JUNK res_0603 219.300000 27.500000 2 90 R1484 Res_49R9_Ohm_0603 SY_JUNK res_0603 221.000000 27.500000 2 90 C1485 Cap_1_nFd_0603 SY_JUNK cap_0603 214.000000 27.500000 2 270 C1486 Cap_100_nFd_0603 SY_JUNK cap_0603 207.000000 43.500000 2 90 C1487 Cap_100_nFd_0603 SY_JUNK cap_0603 208.700000 43.500000 2 90 C1488 Cap_100_nFd_0603 SY_JUNK cap_0603 210.500000 43.500000 2 90 C1489 Cap_100_nFd_0603 SY_JUNK cap_0603 212.200000 43.500000 2 90 R1486 Res_49R9_Ohm_0603 SY_JUNK res_0603 215.800000 43.500000 2 270 R1487 Res_49R9_Ohm_0603 SY_JUNK res_0603 217.500000 43.500000 2 270 R1488 Res_49R9_Ohm_0603 SY_JUNK res_0603 219.300000 43.500000 2 270 R1489 Res_49R9_Ohm_0603 SY_JUNK res_0603 221.000000 43.500000 2 270 C1490 Cap_1_nFd_0603 SY_JUNK cap_0603 214.000000 43.500000 2 90 # MIGT>---------------------------------------------- # MIGT> done substituting from # MIGT>---------------------------------------------- # MIGT> V1.0 -- Wed Feb 15 13:01:31 2017 # MIGT> begin substituting from -- instance #7/7 # MIGT>---------------------------------------------- # # Rear Ethernet TRC Components Template File # # for Etherent Transformer #10 # ---- # # # Original Rev. 23-Apr-2015 # Most Recent Rev. 29-Jun-2016 # # # This file holds the TRC Components for 2 complete # 10/100/1000 Base-T Ethernet connections that are # services by Ethernet "Transformer" number 10. # # - First place the Ethernet Transformer #10 itself. # # - Then the 4 capacitors are the Phys side center tap bypass caps. # # - Then the 4 resistors are the Cable side center tap Bob Smith Termination. # # - Then the 1 nFd capacitor ties the Bob Smith Termination to ground. # # - First there are all 9 components for one Ethernet connection # and then the 9 components for the other Ethernet connection # that is serviced by this Ethernet "Transformer". # # The contents of this file will be shifted by Delta_X Delta_Y # before they are actually placed in the design. # # This file holds the RC Components for # Etherent "Transformer" Number: 10 # # # Board_Location # Ref Part_Number Symbol Geometry X Y Properties #----- ----------- ------ ------------------ -------------- ---------- # TRNS10 Pulse_HX5201NL SY_JUNK DUAL_BASE_T_MAG 234.000000 35.500000 1 270 C1491 Cap_100_nFd_0603 SY_JUNK cap_0603 227.000000 27.500000 2 270 C1492 Cap_100_nFd_0603 SY_JUNK cap_0603 228.700000 27.500000 2 270 C1493 Cap_100_nFd_0603 SY_JUNK cap_0603 230.500000 27.500000 2 270 C1494 Cap_100_nFd_0603 SY_JUNK cap_0603 232.200000 27.500000 2 270 R1491 Res_49R9_Ohm_0603 SY_JUNK res_0603 235.800000 27.500000 2 90 R1492 Res_49R9_Ohm_0603 SY_JUNK res_0603 237.500000 27.500000 2 90 R1493 Res_49R9_Ohm_0603 SY_JUNK res_0603 239.300000 27.500000 2 90 R1494 Res_49R9_Ohm_0603 SY_JUNK res_0603 241.000000 27.500000 2 90 C1495 Cap_1_nFd_0603 SY_JUNK cap_0603 234.000000 27.500000 2 270 C1496 Cap_100_nFd_0603 SY_JUNK cap_0603 227.000000 43.500000 2 90 C1497 Cap_100_nFd_0603 SY_JUNK cap_0603 228.700000 43.500000 2 90 C1498 Cap_100_nFd_0603 SY_JUNK cap_0603 230.500000 43.500000 2 90 C1499 Cap_100_nFd_0603 SY_JUNK cap_0603 232.200000 43.500000 2 90 R1496 Res_49R9_Ohm_0603 SY_JUNK res_0603 235.800000 43.500000 2 270 R1497 Res_49R9_Ohm_0603 SY_JUNK res_0603 237.500000 43.500000 2 270 R1498 Res_49R9_Ohm_0603 SY_JUNK res_0603 239.300000 43.500000 2 270 R1499 Res_49R9_Ohm_0603 SY_JUNK res_0603 241.000000 43.500000 2 270 C1500 Cap_1_nFd_0603 SY_JUNK cap_0603 234.000000 43.500000 2 90 # MIGT>---------------------------------------------- # MIGT> done substituting from