# # MGT_AVAUX Supply # # DCDC 4 Converter Nets # ------------------------- # # # Original Rev. 27-Mar-2015 # Current Rev. 12-Jul-2016 # # # # This file holds all of the nets for the DCDC 4 supply. # # This is the MGT_AVAUX supply 1.800 V at 3 Amps. # # This Hub Module supply uses a LT1764A linear # regulator for this supply. # # # Connect the regulator's V_Input, V_Output, and Ground terminals: # NET 'FLTR_3V3_DCDC4' DCDC4-2 NET 'MGT_AVAUX' DCDC4-4 NET 'GROUND' DCDC4-3 DCDC4-6 # # Connect this regulator's Input Filter: # NET 'FLTR_3V3_DCDC4' C1151-2 C1152-2 NET 'GROUND' C1151-1 C1152-1 # # Connect this regulator's Output Filter: # NET 'MGT_AVAUX' C1154-1 C1155-1 DZ1151-1 NET 'GROUND' C1154-2 C1155-2 DZ1151-2 # # Connect this regulator's SHUT_DOWN_B terminal: # NET 'DCDC4_SHDN_B' DCDC4-1 R1151-2 NET 'FLTR_3V3_DCDC4' R1151-1 # # Connect this regulator's SENSE_ADJUST terminal: # NET 'DCDC4_ADJUST' DCDC4-5 R1153-2 C1153-1 NET 'MGT_AVAUX' R1152-2 NET 'DCDC4_TRM_TOP' R1152-1 R1153-1 C1153-2 NET 'DCDC4_TRM_BOT' R1154-1 R1153-3 NET 'GROUND' R1154-2 # # BULK_3V3 Input Filter for high frequency noise # NET 'BULK_3V3' L1151-1 C1150-2 NET 'FLTR_3V3_DCDC4' L1151-2 NET 'GROUND' C1150-1