# # IPMC: Hardware Address, Handle Switch, IPMBuses # ---------------------------------------------------- # # # Original Rev. 15-Apr-2015 # Current Rev. 17-Jan-2017 # # # # This file holds all of the nets for the IPMC: # # - Hardware Slot Address from the Zone 1 Connector. # # - The Handle Switch for card hot-swap. # # - The "A" and "B" IPMBus connections through the # Zone 1 Connector to the Shelf Manager. # # - The Management I2C Bus from the IPMC to the # FRU&SDR EEPROM and to the Power Entry Module. # # - All of the associated connections to the # M24256 I2C Serial EEPROM the FRU&SDR EEPROM. # # # # Slot Hardware Address Lines # NET 'HW_ADRS_0' P10-5 IPMC-115 NET 'HW_ADRS_1' P10-6 IPMC-237 NET 'HW_ADRS_2' P10-7 IPMC-116 NET 'HW_ADRS_3' P10-8 IPMC-238 NET 'HW_ADRS_4' P10-9 IPMC-117 NET 'HW_ADRS_5' P10-10 IPMC-239 NET 'HW_ADRS_6' P10-11 IPMC-118 NET 'HW_ADRS_7' P10-12 IPMC-240 # # And the Filters on the Hardware Addres Signals. # NET 'HW_ADRS_0' C1551-1 R1551-2 NET 'HW_ADRS_1' C1552-2 R1552-1 NET 'HW_ADRS_2' C1553-1 R1553-2 NET 'HW_ADRS_3' C1554-2 R1554-1 NET 'HW_ADRS_4' C1555-1 R1555-2 NET 'HW_ADRS_5' C1556-2 R1556-1 NET 'HW_ADRS_6' C1557-1 R1557-2 NET 'HW_ADRS_7' C1558-2 R1558-1 NET 'GROUND' C1551-2 C1552-1 NET 'GROUND' C1553-2 C1554-1 NET 'GROUND' C1555-2 C1556-1 NET 'GROUND' C1557-2 C1558-1 NET 'IPMC_3V3' R1551-1 R1552-2 NET 'IPMC_3V3' R1553-1 R1554-2 NET 'IPMC_3V3' R1555-1 R1556-2 NET 'IPMC_3V3' R1557-1 R1558-2 # # Handle Switch Connection to the IPMC # # On 5-Dec-16 the pcb mount handle switch scheme was # abandon in favor of the Elma type of front panel with # the switch in the handle and the connection to the pcb # made with discrete wire runs to a Molex connector. # # I will use a Molex 53047-0310 connector on the Hub pcb. # # This mates with the Molex 51021-0300 on the Elma switch # assembly. # # There is still the issue of the required polarity of the # switch to work with the supplied IPMC module and the # major problem that the people who made the IPMC want you # to run the switch on the Hot side of the line - a stupid # dangerous setup. R961 is to limit worst case current # from IPMC_3V3_SRC into the handle switch circuit. # # Because I do not understand the switch polarity I'm mounting # it in 3 vias so that I can rotate it by 180 deg as necassary. # # The assembly house will not install this connector. # This is a through-hole part that we can install during # MSU Final Assembly. # NET 'IPMC_3V3_SRC' R961-1 NET 'Handle_SW_SRC' R961-2 Wterm72-1 NET 'Handle_Switch' Wterm71-1 IPMC-224 NET 'Handle_Switch' C1559-2 R1559-1 NET 'GROUND' C1559-1 R1559-2 NET 'No_Conn_Wterm63' Wterm73-1 # # IPMBus connections: Zone 1 Connector to IPMC # NET 'IPMBus_A_SCL' P10-13 IPMC-120 NET 'IPMBus_A_SDA' P10-14 IPMC-121 NET 'IPMBus_B_SCL' P10-15 IPMC-242 NET 'IPMBus_B_SDA' P10-16 IPMC-243 # # The +12V Isolated Power Supply Module # Enable Signal from the IPMC # # Note that jumpers JMP5 and JMP6 are used to control # whether the IPMC controls the power supply startup # on the Hub Module in the normal way or whether the # enable signal is always given to the Isolated +12V # supply and to the Hub's power supply control logic. # # - Install JMP5 for normal IPMC control of startup. # # - Install JMP6 for immediate startup of the Hub # i.e. ignore the IPMC's Payload Power Control. # NET 'IPMC_Enable_12V' IPMC-225 JMP5-1 NET 'Hub_Power_Enable' JMP6-2 JMP5-2 R956-2 NET 'IPMC_3V3' JMP6-1 NET 'Enable_LED_Anode' R956-1 # # The Management I2C Bus and its connection to the # FRU&SDR EEPROM and to the Power Entry Module. # # Note that the actual net connections to the # Power Entry Module are defined in the nets file # atca_power_entry_nets # NET 'IPMC_MGT_I2C_SDA' IPMC-221 U41-5 NET 'IPMC_MGT_I2C_SCK' IPMC-220 U41-6 # # Associated connections to the FRU&SDR EEPROM # and its bypass capacitor. NET 'IPMC_3V3' U41-8 C1570-1 NET 'GROUND' U41-4 C1570-2 NET 'GROUND' U41-1 U41-2 U41-3 NET 'No_Conn_U41_pin_WC' U41-7