IPMC Pinout Data Rendered Into a Usable Form Rev. 26-Mar-2015 ---------------------------------------------- From: LAPP IPMC Mezzanine V1.6 21-June-2014 IPMC to AMC Nbr Name Dir uC Description -- ----------- --- ---- -------------------- 1 GND 2 PS1#_0 IN IPMC Low level indicates that the AMC module is inserted in the carrier. 3 Enable#_0 OUT IPMC When active, indicates to the AMC module that it is fully inserted in the carrier. 4 IPMB-L_Enable_0 OUT IPMC Connect AMC to the IPMB-L bus. 5 MP_Enable_0 OUT IPMC Activate the Management Power (+3.3V to AMC) 6 PWR_Enable_0 OUT IPMC Activate the module Payload Power (+12V to AMC). 7 MP_Good_0 IN IPMC Asserted when the Management Power voltage are within the required levels. 8 PWR_Good_0 IN IPMC Asserted when the Payload Power voltage are within the required levels. 9 MP_Fault_0 IN IPMC Asserted when the Management Power current reaches the limit 10 PWR_Fault_0 IN IPMC Asserted when the Payload Power current reaches the limit 11 PWR_ORing_0 OUT IPMC Optional - for 12V redundancy 12 GND 13 PS1#_2 IN IPMC Low level indicates that the AMC module is inserted in the carrier. 14 Enable#_2 OUT IPMC When active, indicates to the AMC module that it is fully inserted in the carrier. 15 IPMB-L_Enable_2 OUT IPMC Connect AMC to the IPMB-L bus. 16 MP_Enable_2 OUT IPMC Activate the Management Power (+3.3V to AMC) 17 PWR_Enable_2 OUT IPMC Activate the module Payload Power (+12V to AMC). 18 MP_Good_2 IN IPMC Asserted when the Management Power voltage are within the required levels. 19 PWR_Good_2 IN IPMC Asserted when the Payload Power voltage are within the required levels. 20 MP_Fault_2 IN IPMC Asserted when the Management Power current reaches the limit 21 PWR_Fault_2 IN IPMC Asserted when the Payload Power current reaches the limit 22 PWR_ORing_2 OUT IPMC Optional - for 12V redundancy 23 GND 24 PS1#_4 IN IPMC Low level indicates that the AMC module is inserted in the carrier. 25 Enable#_4 OUT IPMC When active, indicates to the AMC module that it is fully inserted in the carrier. 26 IPMB-L_Enable_4 OUT IPMC Connect AMC to the IPMB-L bus. 27 MP_Enable_4 OUT IPMC Activate the Management Power (+3.3V to AMC) 28 PWR_Enable_4 OUT IPMC Activate the module Payload Power (+12V to AMC). 29 MP_Good_4 IN IPMC Asserted when the Management Power voltage are within the required levels. 30 PWR_Good_4 IN IPMC Asserted when the Payload Power voltage are within the required levels. 31 MP_Fault_4 IN IPMC Asserted when the Management Power current reaches the limit 32 PWR_Fault_4 IN IPMC Asserted when the Payload Power current reaches the limit 33 PWR_ORing_4 OUT IPMC Optional - for 12V redundancy 34 GND 35 PS1#_6 IN IPMC Low level indicates that the AMC module is inserted in the carrier. 36 Enable#_6 OUT IPMC When active, indicates to the AMC module that it is fully inserted in the carrier. 37 IPMB-L_Enable_6 OUT IPMC Connect AMC to the IPMB-L bus. 38 MP_Enable_6 OUT IPMC Activate the Management Power (+3.3V to AMC) 39 PWR_Enable_6 OUT IPMC Activate the module Payload Power (+12V to AMC). 40 MP_Good_6 IN IPMC Asserted when the Management Power voltage are within the required levels. 41 PWR_Good_6 IN IPMC Asserted when the Payload Power voltage are within the required levels. 42 MP_Fault_6 IN IPMC Asserted when the Management Power current reaches the limit 43 PWR_Fault_6 IN IPMC Asserted when the Payload Power current reaches the limit 44 PWR_ORing_6 OUT IPMC Optional - for 12V redundancy 45 GND 46 PS1#_8 IN IPMC Low level indicates that the AMC module is inserted in the carrier. 47 Enable#_8 OUT IPMC When active, indicates to the AMC module that it is fully inserted in the carrier. 48 IPMB-L_Enable_8 OUT IPMC Connect AMC to the IPMB-L bus. 49 MP_Enable_8 OUT IPMC Activate the Management Power (+3.3V to AMC) 50 PWR_Enable_8 OUT IPMC Activate the module Payload Power (+12V to AMC). 51 MP_Good_8 IN IPMC Asserted when the Management Power voltage are within the required levels. 52 PWR_Good_8 IN IPMC Asserted when the Payload Power voltage are within the required levels. 53 MP_Fault_8 IN IPMC Asserted when the Management Power current reaches the limit 54 PWR_Fault_8 IN IPMC Asserted when the Payload Power current reaches the limit 55 PWR_ORing_8 OUT IPMC Optional - for 12V redundancy 56 GND 57 Uart_Tx OUT IOIF UART transmit signal 58 Uart_CTS IN IOIF UART Clear To Send signal 59 GND 60 Uart_Rx IN IOIF UART receive signal 61 Uart_RTS OUT IOIF UART Request To Send signal 62 GND 63 IPM_IO_0 INOUT IOIF IPM I/O 0 for payload interface 64 IPM_IO_1 INOUT IOIF IPM I/O 1 for payload interface 65 VCC 66 IPM_IO_4 INOUT IOIF IPM I/O 4 for payload interface 67 IPM_IO_5 INOUT IOIF IPM I/O 5 for payload interface 68 VCC 69 IPM_IO_8 INOUT IOIF IPM I/O 8 for payload interface 70 IPM_IO_9 INOUT IOIF IPM I/O 9 for payload interface 71 VCC 72 IPM_IO_12 INOUT IOIF IPM I/O 12 for payload interface 73 IPM_IO_13 INOUT IOIF IPM I/O 13 for payload interface 74 VCC 75 USR_0 INOUT IOIF User IO pin 0 76 USR_1 INOUT IOIF User IO pin 1 77 VCC 78 USR_4 INOUT IOIF User IO pin 4 79 USR_5 INOUT IOIF User IO pin 5 80 VCC 81 USR_8 INOUT IOIF User IO pin 8 82 USR_9 INOUT IOIF User IO pin 9 83 VCC 84 USR_12 INOUT IOIF User IO pin 12 85 USR_13 INOUT IOIF User IO pin 13 86 VCC 87 USR_16 INOUT IOIF User IO pin 16 88 USR_17 INOUT IOIF User IO pin 17 89 GND 90 USR_20 INOUT IOIF User IO pin 20 91 USR_22 INOUT IOIF User IO pin 22 92 USR_24 INOUT IOIF User IO pin 24 93 USR_26 INOUT IOIF User IO pin 26 94 USR_28 INOUT IOIF User IO pin 28 95 USR_30 INOUT IOIF User IO pin 30 96 USR_32 INOUT IOIF User IO pin 32 97 GND 98 USR_34 INOUT IOIF User IO pin 34 99 USB_Vbus IN IOIF USB Vbus +5V from USB 100 USB_Dp INOUTpu IOIF USB data + 101 USB_Dn INOUTpu IOIF USB data - 102 GND 103 ATCA_Blue_LED OUT+5V IPMC Front panel blue led (mandatory). +5V level. 104 ATCA_LED1 OUT IPMC Front panel LED 1 (Amber or Red, mandatory) 105 ATCA_LED2 OUT IPMC Front panel LED 2 (Green, optional) 106 ATCA_LED3 OUT IPMC Front panel LED 3 (Amber, optional) 107 GND 108 Master_TRST OUTpu IOIF Master JTAG Test ReSeT signal 109 Master_TDO OUTpu IOIF Master JTAG Test Data Out signal 110 Master_TMS OUTpu IOIF Master JTAG Test Mode Select signal 111 GND 112 TDO OUTpu JTAG TDO 113 TMS INpu JTAG TMS 114 GND 115 HA0 IN IPMC Hardware address 0 116 HA2 IN IPMC Hardware address 2 117 HA4 IN IPMC Hardware address 4 118 HA6 IN IPMC Hardware address 6 119 GND 120 IPMB-A_SCL INOUT IPMC IPMB-A I2C clock 121 IPMB-A_SDA INOUT IPMC IPMB-A I2C data 122 GND 123 GND 124 PS1#_1 IN IPMC Low level indicates that the AMC module is inserted in the carrier. 125 Enable#_1 OUT IPMC When active, indicates to the AMC module that it is fully inserted in the carrier. 126 IPMB-L_Enable_1 OUT IPMC Connect AMC to the IPMB-L bus. 127 MP_Enable_1 OUT IPMC Activate the Management Power (+3.3V to AMC) 128 PWR_Enable_1 OUT IPMC Activate the module Payload Power (+12V to AMC). 129 MP_Good_1 IN IPMC Asserted when the Management Power voltage are within the required levels. 130 PWR_Good_1 IN IPMC Asserted when the Payload Power voltage are within the required levels. 131 MP_Fault_1 IN IPMC Asserted when the Management Power current reaches the limit 132 PWR_Fault_1 IN IPMC Asserted when the Payload Power current reaches the limit 133 PWR_ORing_1 OUT IPMC Optional - for 12V redundancy 134 GND 135 PS1#_3 IN IPMC Low level indicates that the AMC module is inserted in the carrier. 136 Enable#_3 OUT IPMC When active, indicates to the AMC module that it is fully inserted in the carrier. 137 IPMB-L_Enable_3 OUT IPMC Connect AMC to the IPMB-L bus. 138 MP_Enable_3 OUT IPMC Activate the Management Power (+3.3V to AMC)P 139 PWR_Enable_3 OUT IPMC Activate the module Payload Power (+12V to AMC). 140 MP_Good_3 IN IPMC Asserted when the Management Power voltage are within the required levels. 141 PWR_Good_3 IN IPMC Asserted when the Payload Power voltage are within the required levels. 142 MP_Fault_3 IN IPMC Asserted when the Management Power current reaches the limit 143 PWR_Fault_3 IN IPMC Asserted when the Payload Power current reaches the limit 144 PWR_ORing_3 OUT IPMC Optional - for 12V redundancy 145 GND 146 PS1#_5 IN IPMC Low level indicates that the AMC module is inserted in the carrier. 147 Enable#_5 OUT IPMC When active, indicates to the AMC module that it is fully inserted in the carrier. 148 IPMB-L_Enable_5 OUT IPMC Connect AMC to the IPMB-L bus. 149 MP_Enable_5 OUT IPMC Activate the Management Power (+3.3V to AMC) 150 PWR_Enable_5 OUT IPMC Activate the module Payload Power (+12V to AMC). 151 MP_Good_5 IN IPMC Asserted when the Management Power voltage are within the required levels. 152 PWR_Good_5 INpu IPMC Asserted when the Payload Power voltage are within the required levels. 153 MP_Fault_5 IN IPMC Asserted when the Management Power current reaches the limit 154 PWR_Fault_5 IN IPMC Asserted when the Payload Power current reaches the limit 155 PWR_ORing_5 OUT IPMC Optional - for 12V redundancy 156 GND 157 PS1#_7 IN IPMC Low level indicates that the AMC module is inserted in the carrier. 158 Enable#_7 OUT IPMC When active, indicates to the AMC module that it is fully inserted in the carrier. 159 IPMB-L_Enable_7 OUT IPMC Connect AMC to the IPMB-L bus. 160 MP_Enable_7 OUT IPMC Activate the Management Power (+3.3V to AMC) 161 PWR_Enable_7 OUT IPMC Activate the module Payload Power (+12V to AMC). 162 MP_Good_7 IN IPMC Asserted when the Management Power voltage are within the required levels. 163 PWR_Good_7 IN IPMC Asserted when the Payload Power voltage are within the required levels. 164 MP_Fault_7 IN IPMC Asserted when the Management Power current reaches the limit 165 PWR_Fault_7 IN IPMC Asserted when the Payload Power current reaches the limit 166 PWR_ORing_7 OUT IPMC Optional - for 12V redundancy 167 GND 168 IPMB-L_SCL INOUTpu IPMC IPMB-L I2C clock 169 IPMB-L_SDA INOUTpu IPMC IPMB-L I2C data 170 GND 171 Eth_Tx+/Gb_A+ INOUT Tx+ of the Ethernet PHY (OUT) - A+ of the Gigabit Ethernet PHY (INOUT) 172 Eth_Tx-/Gb_A- INOUT Tx- of the Ethernet PHY (OUT) - A- of the Gigabit Ethernet PHY (INOUT) 173 GND 174 Eth_Rx+/Gb_B+ INOUT Rx+ of the Ethernet PHY (IN) - B+ of the Gigabit Ethernet PHY (INOUT) 175 Eth_Rx-/Gb_B- INOUT Rx- of the Ethernet PHY (IN) - B- of the Gigabit Ethernet PHY (INOUT) 176 GND 177 Gb_C+ INOUT C+ of the Gigabit Ethernet PHY 178 Gb_C- INOUT C- of the Gigabit Ethernet PHY 179 GND 180 Gb_D+ INOUT D+ of the Gigabit Ethernet PHY 181 Gb_D- INOUT D- of the Gigabit Ethernet PHY 182 GND 183 Sensor_SCL OUTpu IOIF I2C bus clock for sensor interface 184 Sensor_SDA INOUTpu IOIF I2C bus data for sensor interface 185 GND 186 IPM_IO_2 INOUT IOIF IPM I/O 2 for payload interface 187 IPM_IO_3 INOUT IOIF IPM I/O 3 for payload interface 188 IPM_IO_6 INOUT IOIF IPM I/O 6 for payload interface 189 IPM_IO_7 INOUT IOIF IPM I/O 7 for payload interface 190 GND 191 IPM_IO_10 INOUT IOIF IPM I/O 10 for payload interface 192 IPM_IO_11 INOUT IOIF IPM I/O 11 for payload interface 193 GND 194 IPM_IO_14 INOUT IOIF IPM I/O 14 for payload interface 195 IPM_IO_15 INOUT IOIF IPM I/O 15 for payload interface 196 GND 197 USR_2 INOUT IOIF User IO pin 2 198 USR_3 INOUT IOIF User IO pin 3 199 GND 200 USR_6 INOUT IOIF User IO pin 6 201 USR_7 INOUT IOIF User IO pin 7 202 GND 203 USR_10 INOUT IOIF User IO pin 10 204 USR_11 INOUT IOIF User IO pin 11 205 GND 206 USR_14 INOUT IOIF User IO pin 14 207 USR_15 INOUT IOIF User IO pin 15 208 GND 209 USR_18 INOUT IOIF User IO pin 18 210 USR_19 INOUT IOIF User IO pin 19 211 GND 212 USR_21 INOUT IOIF User IO pin 21 213 USR_23 INOUT IOIF User IO pin 23 214 USR_25 INOUT IOIF User IO pin 25 215 USR_27 INOUT IOIF User IO pin 27 216 USR_29 INOUT IOIF User IO pin 29 217 USR_31 INOUT IOIF User IO pin 31 218 USR_33 INOUT IOIF User IO pin 33 219 GND 220 Mgt_I2C_SCL OUTpu IOIF I2C bus clock for power management module 221 Mgt_I2C_SDA INOUTpu IOIF I2C bus data for power management module 222 GND 223 Ext_RST_n OUTpu IPMC External Reset signal for payload cold reset 224 Handle_Switch IN IPMC Front panel handle switch for board insertion detection 225 12V_Enable OUTpd IOIF Enable DC-DC (-48V to 12V) payload power 226 Alarm_A IN IOIF Alarm from power management module for -48V_A 227 Alarm_B IN IOIF Alarm from power management module for -48V_B 228 PowerGood_A IN IOIF Power good from power management module -48V_A 229 PowerGood_B IN IOIF Power good from power management module -48V_B 230 GND 231 Master_TCK OUTpd IOIF Master JTAG Test Clock signal 232 Master_TDI INpu IOIF Master JTAG Test Data In signal 233 GND 234 TCK INpd JTAG TCK 235 TDI INpu JTAG TDI 236 GND 237 HA1 IN IPMC Hardware address 1 238 HA3 IN IPMC Hardware address 3 239 HA5 IN IPMC Hardware address 5 240 HA7 IN IPMC Hardware address 7 241 GND 242 IPMB-B_SCL INOUT IPMC IPMB-B I2C clock 243 IPMB-B_SDA INOUT IPMC IPMB-B I2C data 244 GND