---------------------------------------------------------------------- Collection of eye diagram for rx: hub1.Q125.ch0/hub1.GT.ch44 ---------------------------------------------------------------------- [Jul 25 17:03:45 2023]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 44 Value after writing: 44 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 3.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [Jul 25 17:03:56 2023]: Finished collection process. Required 0 realignments. Open Area: 61.6% (20160) Horizontal Opening: 72.7% (96) Vertical Opening: 100.0% (248)