---------------------------------------------------------------------- Collection of eye diagram for rx: hub2.Q227.ch3/hub2.GT.ch15 ---------------------------------------------------------------------- [Aug 7 14:31:39 2023]: Beginning collection process. Setting prescale to 0 Value after writing: 0 Setting mgtchselect to 15 Value after writing: 15 Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 3.00 seconds) ... Timeout of 3.00 seconds reached waiting for eye data ready. Lowering eye_go, then performing realignment. Lowering eye_go Value of eye_go after lowering: 0 Performing realignment. [Aug 7 14:31:59 2023]: Realignment finished. Reattempting collection process. Lowering eye_go Value of eye_go after lowering: 0 Issuing eye diagram reset, waiting for eye_datardy low ... Eye_datardy is low after 1 reset attempts. Raising eye_go. Value of eye_go after raising: 1 Waiting for eye_datardy high (timeout of 3.00 seconds) ... Eye data ready in 2.00 seconds. Proceeding to obtain data from registers. Collecting eye diagram data from registers. [Aug 7 14:32:10 2023]: Finished collection process. Required 1 realignments. Open Area: 52.8% (17296) Horizontal Opening: 66.7% (88) Vertical Opening: 100.0% (248)