Level 1 Trigger Framework and Level 1 Calorimeter Trigger Power Supply Monitoring Points ---------------------------------------------------------- Original Rev. 7-JAN-1993 Current Rev. 1-DEC-2003 The following table shows for each rack in the Level 1 Trigger Framework and Level 1 Calorimeter Trigger all of the power supplies that are used a given rack and the "name" by which the power supply is identified. Power Supply Voltage to Rack ID be Monitored and Its Name ------- ------------------------------------ M101 + 5.0 Volts \ + 3.3 Volts | L1 Cal Trig Output and Readout - 2.0 Volts | M101 Top VIPA Crate and M101 Middle Crate - 4.5 Volts / + 5.0 Volts \ + 3.3 Volts | Routing Master - 2.0 Volts | M101 Bottom Crate - 4.5 Volts / M103 + 5.0 Volts \ L1 Calorimeter Trigger Control Crate - 5.2 Volts / Power Supply in M104 Top + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +1:+4 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +1:+4 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M104 + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -1:-4 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -1:-4 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M105 + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 2 Eta 1:8 - 4.5 Volts | Power Supply in M106 Top - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +5:+8 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +5:+8 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M106 + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -5:-8 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -5:-8 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M107 + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 3 - 4.5 Volts | Power Supply in M108 Top - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +9:+12 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +9:+12 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M108 + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -9:-12 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -9:-12 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M109 + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 2 Eta 9:16 - 4.5 Volts | Power Supply in M110 Top - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +13:+16 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +13:+16 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M110 + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -13:-16 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -13:-16 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M111 + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 2 Eta 17:20 - 4.5 Volts | Power Supply in M112 Top - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +17:+20 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta +17:+20 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M112 + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -17:-20 Phi 1:16 - 4.5 Volts | - 5.2 Volts / + 5.0 Volts \ - 2.0 Volts | Cal Trig Tier 1 Eta -17:-20 Phi 17:32 - 4.5 Volts | - 5.2 Volts / M122 + 5.0 Volts \ + 3.3 Volts | Trigger Framework M122 Top Crate - 2.0 Volts | - 4.5 Volts / + 5.0 Volts \ + 3.3 Volts | Trigger Framework M122 Middle Crate - 2.0 Volts | - 4.5 Volts / + 5.0 Volts \ + 3.3 Volts | Trigger Framework M122 Bottom Crate - 2.0 Volts | - 4.5 Volts / M123 + 5.0 Volts \ + 3.3 Volts | Trigger Framework M123 Top Crate - 2.0 Volts | - 4.5 Volts / + 5.0 Volts \ + 3.3 Volts | Trigger Framework M123 Middle Crate - 2.0 Volts | - 4.5 Volts / + 5.0 Volts \ + 3.3 Volts | Trigger Framework M123 Bottom Crate - 2.0 Volts | - 4.5 Volts / M124 + 5.0 Volts \ + 3.3 Volts | SCL Hub-End Crate - 2.0 Volts | Upper M124 VIPA Crate - 5.2 Volts / & TCC's VME Communication Crate + 5.0 Volts \ + 3.3 Volts | Trigger Framework Readout - 2.0 Volts | (with L2 Global Answer receiver de-mux card) - 5.2 Volts / Lower M124 VIPA Crate ///////////////////////////////////////////////////////////////////////////// Number of Rack Supplies Monitored ---- ------------------ M101 8 M103 10 M104 8 M105 12 M106 8 M107 12 M108 8 M109 12 M110 8 M111 12 M112 8 M122 12 M123 12 M124 8 + -------- 138 Each Shea 1553 can monitor 64 inputs. As it stands with 2 Shea 1551 boxes, we have only 128 inputs. ///////////////////////////////////////////////////////////////////////////// List of the Voltage Monitoring Connections that are Currently Connected ----------------------------------------------------------------------- Current Rev. 15-MAY-2002 Voltages being Monitored JBOX/ DB-9 Shea unit ----------------------------- Cable S/N Shea Letter Channels Rack Crate --------- ----- ------ --------- ---- ----------------------- VM-M103-A 1 P10 C 40 - 43 M103 Cal Trig Control Crate VM-M103-B 1 P10 D 44 - 47 M103 PHI 1:16 ETA +1:+4 VM-M103-C 1 P5 E 0 - 3 M103 PHI 17:32 ETA +1:+4 VM-M104-B 1 P5 F 4 - 7 M104 PHI 1:16 ETA -1:-4 VM-M104-C 1 P5 G 8 - 11 M104 PHI 17:32 ETA -1:-4 VM-M105-A 1 P5 H 12 - 15 M105 Second Tier ETA +8:-8 VM-M105-B 1 P11 I 48 - 51 M105 PHI 1:16 ETA +5:+8 VM-M105-C 1 P11 J 52 - 55 M105 PHI 17:32 ETA +5:+8 VM-M106-B 1 P11 K 56 - 59 M106 PHI 1:16 ETA -5:-8 VM-M106-C 1 P11 L 60 - 63 M106 PHI 17:32 ETA -5:-8 VM-M107-A 1 P6 M 16 - 19 M107 Third Tier VM-M107-B 1 P6 N 20 - 23 M107 PHI 1:16 ETA +9:+12 VM-M107-C 1 P6 O 24 - 27 M107 PHI 17:32 ETA +9:+12 VM-M108-B 1 P6 P 28 - 31 M108 PHI 1:16 ETA -9:-12 VM-M108-C 2 P10 A 32 - 35 M108 PHI 17:32 ETA -9:-12 VM-M109-A 2 P10 B 36 - 39 M109 Second Tier ETA 9:16 VM-M109-B 2 P10 C 40 - 43 M109 PHI 1:16 ETA +13:+16 VM-M109-C 2 P10 D 44 - 47 M109 PHI 17:32 ETA +13:+16 VM-M110-B 2 P5 E 0 - 3 M110 PHI 1:16 ETA -13:-16 VM-M110-C 2 P5 F 4 - 7 M110 PHI 17:32 ETA -13:-16 VM-M111-A 2 P5 G 8 - 11 M111 Second Tier ETA 17:20 VM-M111-B 2 P5 H 12 - 15 M111 PHI 1:16 ETA +17:+20 VM-M111-C 2 P11 I 48 - 51 M111 PHI 17:32 ETA +17:+20 VM-M112-B 2 P11 J 52 - 55 M112 PHI 1:16 ETA -17:-20 VM-M112-C 2 P11 K 56 - 59 M112 PHI 17:32 ETA -17:-20 Channels 32:39 in the first Shea Box are not currently used. Channels 16:31 and 60:63 in the second Shea Box are not currently used. For all the L1 Cal Trig Tier one Crates, i.e. the 20 crates that are labeled "PHI ab:cd ETA +-ef:+-gh" the voltage monitor points are connected to the Shea Channels in the following way: the 1st Shea Channel in the block of 4 monitors a -4.5 Volt supply the 2nd Shea Channel in the block of 4 monitors a +5.0 Volt supply the 3rd Shea Channel in the block of 4 monitors a -2.0 Volt supply the 4th Shea Channel in the block of 4 monitors a -5.2 Volt supply For the 3 Second Tier crates and the 1 Third Tier crate the voltage monitor points are connected to the Shea Channels in the following way: the 1st Shea Channel in the block of 4 monitors a -4.5 Volt supply the 2nd Shea Channel in the block of 4 monitors a -2.0 Volt supply the 3rd Shea Channel in the block of 4 monitors a +5.0 Volt supply the 4th Shea Channel in the block of 4 monitors a -5.2 Volt supply For the single Calorimeter Trigger Control Crate the voltage monitor points are connected to the Shea Channels in the following way: ??? List of Voltage Monitor Cables that are not currently connected --------------------------------------------------------------- VM-M101-C 1 P10 A 32 - 35 not connected yet VM-M102-C 1 P10 B 36 - 39 not connected yet VM-M114-A 2 P11 L 60 - 63 not connected yet ///////////////////////////////////////////////////////////////////////////// Voltage Monitor Signals Listed in Shea Box Channel Order -------------------------------------------------------------- Original Rev. 15-JAN-2003 Current Rev. 10-JUNE-2003 Shea Box Remote Terminal = 25 Shea Box Voltage Monitor Signal Analog --------------------------------------------------------- Channel Power Supply Rack Eta Phi Crate Type -------- ---------------- ---- -------------------- ---------- 0 -4.5 Volt supply M103 eta +1:+4 phi 17:32 Tier 1 1 +5.0 Volt supply M103 eta +1:+4 phi 17:32 Tier 1 2 -2.0 Volt supply M103 eta +1:+4 phi 17:32 Tier 1 3 -5.2 Volt supply M103 eta +1:+4 phi 17:32 Tier 1 4 -4.5 Volt supply M104 eta -1:-4 phi 1:16 Tier 1 5 +5.0 Volt supply M104 eta -1:-4 phi 1:16 Tier 1 6 -2.0 Volt supply M104 eta -1:-4 phi 1:16 Tier 1 7 -5.2 Volt supply M104 eta -1:-4 phi 1:16 Tier 1 8 -4.5 Volt supply M104 eta -1:-4 phi 17:32 Tier 1 9 +5.0 Volt supply M104 eta -1:-4 phi 17:32 Tier 1 10 -2.0 Volt supply M104 eta -1:-4 phi 17:32 Tier 1 11 -5.2 Volt supply M104 eta -1:-4 phi 17:32 Tier 1 12 -4.5 Volt supply M105 eta 1:8 Tier 2 13 -2.0 Volt supply M105 eta 1:8 Tier 2 14 +5.0 Volt supply M105 eta 1:8 Tier 2 15 -5.2 Volt supply M105 eta 1:8 Tier 2 16 -4.5 Volt supply M107 All eta,phi Tier 3 17 -2.0 Volt supply M107 All eta,phi Tier 3 18 +5.0 Volt supply M107 All eta,phi Tier 3 19 -5.2 Volt supply M107 All eta,phi Tier 3 20 -4.5 Volt supply M107 eta +9:+12 phi 1:16 Tier 1 21 +5.0 Volt supply M107 eta +9:+12 phi 1:16 Tier 1 22 -2.0 Volt supply M107 eta +9:+12 phi 1:16 Tier 1 23 -5.2 Volt supply M107 eta +9:+12 phi 1:16 Tier 1 24 -4.5 Volt supply M107 eta +9:+12 phi 17:32 Tier 1 25 +5.0 Volt supply M107 eta +9:+12 phi 17:32 Tier 1 26 -2.0 Volt supply M107 eta +9:+12 phi 17:32 Tier 1 27 -5.2 Volt supply M107 eta +9:+12 phi 17:32 Tier 1 28 -4.5 Volt supply M108 eta -9:-12 phi 1:16 Tier 1 29 +5.0 Volt supply M108 eta -9:-12 phi 1:16 Tier 1 30 -2.0 Volt supply M108 eta -9:-12 phi 1:16 Tier 1 31 -5.2 Volt supply M108 eta -9:-12 phi 1:16 Tier 1 32 +5.0 Volt supply M101 Bottom Crate Routing Master 33 +3.3 Volt supply M101 Bottom Crate Routing Master 34 -2.0 Volt supply M101 Bottom Crate Routing Master 35 -4.5 Volt supply M101 Bottom Crate Routing Master 36 +5.0 Volt supply M101 Mid & Top Crates L1 Cal Trig Readout 37 +3.3 Volt supply M101 Mid & Top Crates L1 Cal Trig Readout 38 -2.0 Volt supply M101 Mid & Top Crates L1 Cal Trig Readout 39 -4.5 Volt supply M101 Mid & Top Crates L1 Cal Trig Readout 40 +5.0 Volt supply M103 L1 Cal Trig Control Crate 41 +5.0 Volt supply M103 L1 Cal Trig Control Crate 42 -5.2 Volt supply M103 L1 Cal Trig Control Crate 43 -5.2 Volt supply M103 L1 Cal Trig Control Crate 44 -4.5 Volt supply M103 eta +1:+4 phi 1:16 Tier 1 45 +5.0 Volt supply M103 eta +1:+4 phi 1:16 Tier 1 46 -2.0 Volt supply M103 eta +1:+4 phi 1:16 Tier 1 47 -5.2 Volt supply M103 eta +1:+4 phi 1:16 Tier 1 48 -4.5 Volt supply M105 eta +5:+8 phi 1:16 Tier 1 49 +5.0 Volt supply M105 eta +5:+8 phi 1:16 Tier 1 50 -2.0 Volt supply M105 eta +5:+8 phi 1:16 Tier 1 51 -5.2 Volt supply M105 eta +5:+8 phi 1:16 Tier 1 52 -4.5 Volt supply M105 eta +5:+8 phi 17:32 Tier 1 53 +5.0 Volt supply M105 eta +5:+8 phi 17:32 Tier 1 54 -2.0 Volt supply M105 eta +5:+8 phi 17:32 Tier 1 55 -5.2 Volt supply M105 eta +5:+8 phi 17:32 Tier 1 56 -4.5 Volt supply M106 eta -5:-8 phi 1:16 Tier 1 57 +5.0 Volt supply M106 eta -5:-8 phi 1:16 Tier 1 58 -2.0 Volt supply M106 eta -5:-8 phi 1:16 Tier 1 59 -5.2 Volt supply M106 eta -5:-8 phi 1:16 Tier 1 60 -4.5 Volt supply M106 eta -5:-8 phi 17:32 Tier 1 61 +5.0 Volt supply M106 eta -5:-8 phi 17:32 Tier 1 62 -2.0 Volt supply M106 eta -5:-8 phi 17:32 Tier 1 63 -5.2 Volt supply M106 eta -5:-8 phi 17:32 Tier 1 Shea Box Remote Terminal = 26 Shea Box Voltage Monitor Signal Analog --------------------------------------------------------- Channel Power Supply Rack Eta Phi Crate Type -------- ---------------- ---- -------------------- ---------- 0 -4.5 Volt supply M110 eta -13:-16 phi 1:16 Tier 1 1 +5.0 Volt supply M110 eta -13:-16 phi 1:16 Tier 1 2 -2.0 Volt supply M110 eta -13:-16 phi 1:16 Tier 1 3 -5.2 Volt supply M110 eta -13:-16 phi 1:16 Tier 1 4 -4.5 Volt supply M110 eta -13:-16 phi 17:32 Tier 1 5 +5.0 Volt supply M110 eta -13:-16 phi 17:32 Tier 1 6 -2.0 Volt supply M110 eta -13:-16 phi 17:32 Tier 1 7 -5.2 Volt supply M110 eta -13:-16 phi 17:32 Tier 1 8 -4.5 Volt supply M111 eta 17:20 Tier 2 9 -2.0 Volt supply M111 eta 17:20 Tier 2 10 +5.0 Volt supply M111 eta 17:20 Tier 2 11 -5.2 Volt supply M111 eta 17:20 Tier 2 12 -4.5 Volt supply M111 eta +17:+20 phi 1:16 Tier 1 13 +5.0 Volt supply M111 eta +17:+20 phi 1:16 Tier 1 14 -2.0 Volt supply M111 eta +17:+20 phi 1:16 Tier 1 15 -5.2 Volt supply M111 eta +17:+20 phi 1:16 Tier 1 16 +5.0 Volt supply M122 All Crates L2 TFW & Per Bunch Scalers 17 +3.3 Volt supply M122 All Crates L2 TFW & Per Bunch Scalers 18 -2.0 Volt supply M122 All Crates L2 TFW & Per Bunch Scalers 19 -4.5 Volt supply M122 All Crates L2 TFW & Per Bunch Scalers 20 +5.0 Volt supply M123 All Crates L1 TFW 21 +3.3 Volt supply M123 All Crates L1 TFW 22 -2.0 Volt supply M123 All Crates L1 TFW 23 -4.5 Volt supply M123 All Crates L1 TFW 24 +5.0 Volt supply M124 All Crates TFW Readout & SCL Hub-End & VME Comm 25 +3.3 Volt supply M124 All Crates TFW Readout & SCL Hub-End & VME Comm 26 -2.0 Volt supply M124 All Crates TFW Readout & SCL Hub-End & VME Comm 27 -5.2 Volt supply M124 All Crates TFW Readout & SCL Hub-End & VME Comm 28:31 Channels 28:31 in this Shea Box are not currently used 32 -4.5 Volt supply M108 eta -9:-12 phi 17:32 Tier 1 33 +5.0 Volt supply M108 eta -9:-12 phi 17:32 Tier 1 34 -2.0 Volt supply M108 eta -9:-12 phi 17:32 Tier 1 35 -5.2 Volt supply M108 eta -9:-12 phi 17:32 Tier 1 36 -4.5 Volt supply M109 eta 9:16 Tier 2 37 -2.0 Volt supply M109 eta 9:16 Tier 2 38 +5.0 Volt supply M109 eta 9:16 Tier 2 39 -5.2 Volt supply M109 eta 9:16 Tier 2 40 -4.5 Volt supply M109 eta +13:+16 phi 1:16 Tier 1 41 +5.0 Volt supply M109 eta +13:+16 phi 1:16 Tier 1 42 -2.0 Volt supply M109 eta +13:+16 phi 1:16 Tier 1 43 -5.2 Volt supply M109 eta +13:+16 phi 1:16 Tier 1 44 -4.5 Volt supply M109 eta +13:+16 phi 17:32 Tier 1 45 +5.0 Volt supply M109 eta +13:+16 phi 17:32 Tier 1 46 -2.0 Volt supply M109 eta +13:+16 phi 17:32 Tier 1 47 -5.2 Volt supply M109 eta +13:+16 phi 17:32 Tier 1 48 -4.5 Volt supply M111 eta +17:+20 phi 17:32 Tier 1 49 +5.0 Volt supply M111 eta +17:+20 phi 17:32 Tier 1 50 -2.0 Volt supply M111 eta +17:+20 phi 17:32 Tier 1 51 -5.2 Volt supply M111 eta +17:+20 phi 17:32 Tier 1 52 -4.5 Volt supply M112 eta -17:-20 phi 1:16 Tier 1 53 +5.0 Volt supply M112 eta -17:-20 phi 1:16 Tier 1 54 -2.0 Volt supply M112 eta -17:-20 phi 1:16 Tier 1 55 -5.2 Volt supply M112 eta -17:-20 phi 1:16 Tier 1 56 -4.5 Volt supply M112 eta -17:-20 phi 17:32 Tier 1 57 +5.0 Volt supply M112 eta -17:-20 phi 17:32 Tier 1 58 -2.0 Volt supply M112 eta -17:-20 phi 17:32 Tier 1 59 -5.2 Volt supply M112 eta -17:-20 phi 17:32 Tier 1 60:63 Channels 60:63 in this Shea Box are not currently used Note that the Tier 2 and Tier 3 power supplies are in a different relative order wrt Shea Box channel numbers. Note the following are the locations of these various components in each rack. M103 Top L1 Cal Trig Control Crate M104 Top Power Supplies for the L1 Cal Trig Control Crate in M103 M105 Top Tier 2 Crate for eta 1:8 M106 Top Power Supplies for the Tier 2 crate in M105 Top M107 Top Tier 3 Crate M108 Top Power Supplies for the Tier 3 crate in M107 Top M109 Top Tier 2 Crate for eta 9:16 M110 Top Power Supplies for the Tier 2 crate in M109 Top M111 Top Tier 2 Crate for eta 17:20 M112 Top Power Supplies for the Tier 2 crate in M111 Top The Middle of all 10 racks is the phi 1:16 Tier 1 Crate and its Power Supplies. The Bottom of all 10 racks is the phi 17:32 Tier 1 Crate and its Power Supplies.