Level 1 Accept Generates Skip Next BX, Scaler Control, Global L1 Fired Strobe, Plus ------------------------------------------------------------ Original Rev. 15-MAY-1997 Current Rev. 15-MAY-1997 A Framework Output Module will be used to generate a number of signals every time a L1 Specific Trigger fires. These signals include: 1. A Skip Next BX signal that is feed into a "Global Disable" input of all 16 of the Trigger Decision Modules. This signal blocks the possibility of the Run II Framework generating a second L1 Trigger on during the tick following a tick where a legitimate L1 Trigger has fired. 2. A Scaler Control signal to keep the appropriate scalers from incrementing during ticks when all L1 Specific Triggers are disabled by the Skip Next BX signal. 3. The Run II L1 Framework will likely require a "Global L1 Fired Strobe" signal. This signal could also be generated on this Framework Output Module. These various signals listed above will likely require different amounts of "stretching and latching" in order to have the proper width to perform their required functions.