Vertial Interconnect Cable Between Modules -------------------------------------------- Rev. 27-JUNE-01 The pinout for the VI Master to Slave cables is: Master Function Slave ------ ---------- ----- C1 Shield C5 \ C2 Blue C6 \ C3 White C7 | C4 No Conn. C8 | | Channel 0 C5 Shield C1 | C6 Blue C2 | C7 White C3 / C8 No Conn. C4 / C9 Shield C5 \ C10 Blue C6 \ C11 White C7 | C12 No Conn. C8 | | Channel 1 C13 Shield C1 | C14 Blue C2 | C15 White C3 / C16 No Conn. C4 / C17 Shield C5 \ C18 Blue C6 \ C19 White C7 | C20 No Conn. C8 | | Channel 2 C21 Shield C1 | C22 Blue C2 | C23 White C3 / C24 No Conn. C4 / C25 Shield C5 \ C26 Blue C6 \ C27 White C7 | C28 No Conn. C8 | | Channel 3 C29 Shield C1 | C30 Blue C2 | C31 White C3 / C32 No Conn. C4 / So between the Master and the Slave, the pairs criss cross but the 2 signals in a differential pair do not cross.