Total Card Mulitplicity for L2 System
Card Allocated Max Contact
Alpha 14 26 R. Martin, rmartin@uic.edu
BIT3 6 6 Philippe Laurens, laurens@pa.msu.edu
CIC 14 14 Greg Snow, gsnow@fnal.gov
FIC 9 9 Jean-Francois Renardy, renardy@hep.saclay.cea.fr
MBT 14 16 Drew Baden, drew@fnal.gov
SFO 13 17 Greg Snow, gsnow@fnal.gov
SLIC 18 18 Mike Fortner, fortner@fnald0.fnal.gov
VTM 9 9 Ed Barsotti, barsotti@fnal.gov
VBD 6 6 Zeller
Max Crate Occupancy and Power Summary
Max Max Pwr 12V max 5V max 3.3V max -5.2V max -12V max
Crate Slots (Watts) (Amps) (Amps) (Amps) (Amps) (Amps)
L2Global 22 1472.3 14 169.5 85 17.75 7
L2CTT 22 1396.8 12 169.5 75 16.5 6
L2Cal 22 1446.8 12 179.5 75 16.5 6
L2FMu 23 1478.6 8 180.9 113 11 4
L2CMu 23 1470.4 4 185.7 129 8.5 2
L2PS 21 1321.3 10 169.5 65 15.25 5
L2 Power Supply (max + 15%) 1953.28 16 214 148 20 8
Min Crate Occupancy and Power Summary
Pwr 12V min 5V min 3.3V min -5.2V min -12V min
Crate Slots (Watts) (Amps) (Amps) (Amps) (Amps) (Amps)
L2Global 10 527.7 4 62.5 30 8.5 2
L2CTT 13 694.8 4 89.5 35 11.5 2
L2Cal 17 1028.7 8 132.5 50 11 4
L2FMu 18 1127.6 4 140.9 93 8.5 2
L2CMu 21 1470.4 4 185.7 129 8.5 2
L2PS 15 794.8 4 109.5 35 11.5 2
L2 Power Supply (max + 15%) 1791.7 9 214 148 13 5