M105 TIER 2 CABLE LABELS 21-MAR-1991 9-MAR-1992 The Tier 2 cables should be labelled as follows: Note: anything within the box should be on the cable. Note: leave S/N blank or draw an underline, DO NOT FILL IN. Note: Some Words {A, B, C, D} == 1 cable labelled 'Some Words A' 1 cable labelled 'Some Words B' 1 cable labelled 'Some Words C' 1 cable labelled 'Some Words D' Note: the syntax of this list is nested, that is, the two lines Some Words {A, B, C, D} Other Words {E, F, G, H} is sixteen (16) cables, not 8. NOTE: These cables have the Reference Sets labelled 1..4, while the Reference Sets are actually numbered 0..3. 1. Counter Tree cables, CHTCR end The label must fit a 50-conductor twist'n'flat cable. 1 each: 1 +-----------------------------------------------+ | {EM Et, Total Et} | 2 | Ref Set 1..4 | 1 | ETA = {+1..+4, -1..-4, +5..+8, -5..-8} | 4 | PHI = {1..8, 9..16, 17..24, 25..32} | 4 | S/N = _________ | --- +-----------------------------------------------+ 1x2x1x4x4 = 32 labels 2. Counter Tree cables, CAT2 end The label must fit a 12-conductor twist'n'flat cable. 1 each: 1 +-----------------------------------------------+ | {EM Et, Total Et} | 2 | Ref Set {1, 2, 3, 4} | 4 | ETA = {+1..+4, -1..-4, +5..+8, -5..-8} | 4 | PHI = {1..8, 9..16, 17..24, 25..32} | 4 | S/N = _________ | --- +-----------------------------------------------+ 1x2x4x4x4 = 128 labels 3. EM, HD Adder Tree cables The label must fit a 34-conductor twist'n'flat cable. 2 each: 2 +-----------------------------------------------+ | {EM, HD} Sum | 2 | ETA = {+1..+4, -1..-4, +5..+8, -5..-8} | 4 | PHI = {1..8, 9..16, 17..24, 25..32} | 4 | S/N = _________ | --- +-----------------------------------------------+ 2x2x4x4 = 64 labels 4. +Px Adder Tree cables The label must fit a 34-conductor twist'n'flat cable. 2 each: 2 +-----------------------------------------------+ | +Px Sum | 1 | ETA = {+1..+4, -1..-4, +5..+8, -5..-8} | 4 | PHI = {1..8, 25..32} | 2 | S/N = _________ | --- +-----------------------------------------------+ 2x1x2x4 = 16 labels 5. -Px Adder Tree cables The label must fit a 34-conductor twist'n'flat cable. 2 each: 2 +-----------------------------------------------+ | -Px Sum | 1 | ETA = {+1..+4, -1..-4, +5..+8, -5..-8} | 4 | PHI = {9..16, 17..24} | 2 | S/N = _________ | --- +-----------------------------------------------+ 2x1x2x4 = 16 labels 6. +Py Adder Tree cables The label must fit a 34-conductor twist'n'flat cable. 2 each: 2 +-----------------------------------------------+ | +Py Sum | 1 | ETA = {+1..+4, -1..-4, +5..+8, -5..-8} | 4 | PHI = {1..8, 9..16} | 2 | S/N = _________ | --- +-----------------------------------------------+ 2x1x2x4 = 16 labels 7. -Py Adder Tree cables The label must fit a 34-conductor twist'n'flat cable. 2 each: 2 +-----------------------------------------------+ | -Py Sum | 1 | ETA = {+1..+4, -1..-4, +5..+8, -5..-8} | 4 | PHI = {17..24, 25..32} | 2 | S/N = _________ | --- +-----------------------------------------------+ 2x1x2x4 = 16 labels This is a total of 16 + 16 + 16 + 16 + 64 + 128 + 32 = 288 labels, of 3 different sizes.