# # Disco-Kraken Net List File # # FPGA Bypass Caps and Power Filters # --------------------------------------- # # # Initial Rev. 16-Nov-2022 # Current Rev. 9-Jan-2025 # # # This net list holds the nets for: # # - FPGA LC Power Filters # # - FPGA ByPass Capacitors # # # CORE Power to the FPGA/CPU 1V05 L101: # ------------------------------------------- # # Bulk_1V05 Power Into Filter NET 'BULK_1V05' L101-1 NET 'BULK_1V05' PVA101A-1 PVA101A-2 PVA101A-3 NET 'BULK_1V05' PVA101B-1 PVA101B-2 PVA101B-3 NET 'BULK_1V05' PVA101C-1 PVA101C-2 PVA101C-3 NET 'BULK_1V05' PVA101D-1 PVA101D-2 PVA101D-3 # Filtered CORE Power NET 'CORE_1V05' L101-2 NET 'CORE_1V05' PVA101E-1 PVA101E-2 PVA101E-3 NET 'CORE_1V05' PVA101F-1 PVA101F-2 PVA101F-3 NET 'CORE_1V05' PVA101G-1 PVA101G-2 PVA101G-3 NET 'CORE_1V05' PVA101H-1 PVA101H-2 PVA101H-3 NET 'CORE_1V05' C101-1 C102-1 # CORE Tantalum Bypass NET 'GROUND' C101-2 C102-2 # Tant Bypass Cap Grounds NET 'CORE_1V05' C103-1 C104-2 C105-1 C106-2 # CORE 22 uFd Bypass NET 'GROUND' C103-2 C104-1 C105-2 C106-1 # Bypass Cap Grounds NET 'CORE_1V05' C107-2 C108-2 C109-2 C110-2 # CORE 2.2 uFd 0603 NET 'GROUND' C107-1 C108-1 C109-1 C110-1 # Bypass Cap Grounds NET 'CORE_1V05' C111-2 C112-2 # CORE under FPGA 0402 NET 'GROUND' C111-1 C112-1 # 470 nFd Bypass Cap Grounds NET 'CORE_1V05' C120-2 C121-1 C122-2 C123-1 # CORE under FPGA 0402 NET 'GROUND' C120-1 C121-2 C122-1 C123-2 # Bypass Cap Grounds NET 'CORE_1V05' C124-2 C125-2 # CORE under FPGA 0402 NET 'GROUND' C124-1 C125-1 # Bypass Cap Grounds # # Transceiver 1V05 Analog Power L102: # ---------------------------------------- # # Bulk_1V05 Power Into Filter NET 'BULK_1V05' L102-1 NET 'BULK_1V05' PVA102A-1 PVA102A-2 PVA102A-3 NET 'BULK_1V05' PVA102B-1 PVA102B-2 PVA102B-3 # Filtered Transceiver 1V05 Analog Power NET 'XCVR_1V05' L102-2 NET 'XCVR_1V05' PVA102C-1 PVA102C-2 PVA102C-3 NET 'XCVR_1V05' PVA102D-1 PVA102D-2 PVA102D-3 NET 'XCVR_1V05' C241-1 # XCVR_1V05 Tantalum Bypass NET 'GROUND' C241-2 # Tant Bypass Cap Grounds NET 'XCVR_1V05' C242-2 C243-1 # XCVR_1V05 22 uFd Bypass NET 'GROUND' C242-1 C243-2 # Bypass Cap Grounds NET 'XCVR_1V05' C244-2 C245-1 # XCVR_1V05 2.2 uFd 0603 NET 'GROUND' C244-1 C245-2 # Bypass Cap Grounds NET 'XCVR_1V05' C246-1 C247-2 # XCVR_1V05 220 nFd 0603 NET 'GROUND' C246-2 C247-1 # Bypass Cap Grounds NET 'XCVR_1V05' C248-2 C249-2 C250-1 # XCVR_1V05 100 nFd 0603 NET 'GROUND' C248-1 C249-1 C250-2 # Bypass Cap Grounds NET 'XCVR_1V05' C151-2 C152-2 C153-2 C154-1 # XCVR_1V05 under FPGA 0402 NET 'GROUND' C151-1 C152-1 C153-1 C154-2 # Bypass Cap Grounds NET 'XCVR_1V05' C155-2 C156-2 C157-1 C158-2 # XCVR_1V05 under FPGA 0402 NET 'GROUND' C155-1 C156-1 C157-2 C158-1 # Bypass Cap Grounds NET 'XCVR_1V05' C159-2 C160-2 C161-1 C162-2 # XCVR_1V05 under FPGA 0402 NET 'GROUND' C159-1 C160-1 C161-2 C162-1 # Bypass Cap Grounds NET 'XCVR_1V05' C163-2 C164-1 C165-2 C166-1 # XCVR_1V05 under FPGA 0402 NET 'GROUND' C163-1 C164-2 C165-1 C166-2 # Bypass Cap Grounds # # FPGA_1V8 Supply for: Programming, HSIO Aux, and Bank #9 I/O # # The FPGA_1V8 Supply comes from the BULK_1V8 Supply via L103: # ------------------------------------------------------------------- # # Bulk_1V8 Power into the Filter NET 'BULK_1V8' L103-2 NET 'BULK_1V8' PVA103A-1 PVA103A-2 PVA103A-3 NET 'BULK_1V8' PVA103B-1 PVA103B-2 PVA103B-3 # Filtered Power to FPGA: Prog, HSIO_Aux, Bank #9 NET 'FPGA_1V8' L103-1 NET 'FPGA_1V8' PVA103C-1 PVA103C-2 PVA103C-3 NET 'FPGA_1V8' PVA103D-1 PVA103D-2 PVA103D-3 NET 'FPGA_1V8' C281-1 C282-2 # FPGA_1V8 330 uFd Tant NET 'GROUND' C281-2 C282-1 # and 22 uFd Ceramic NET 'FPGA_1V8' C171-1 C172-2 C173-2 C174-2 # FPGA_1V8 under FPGA 0402 NET 'GROUND' C171-2 C172-1 C173-1 C174-1 # Bypass Caps Grounds NET 'FPGA_1V8' C175-2 C176-2 C177-2 C178-1 # FPGA_1V8 under FPGA 0402 NET 'GROUND' C175-1 C176-1 C177-1 C178-2 # Bypass Caps Grounds NET 'FPGA_1V8' C179-2 # FPGA_1V8 North of FPGA 0603 NET 'GROUND' C179-1 # Bypass Caps Grounds NET 'FPGA_1V8' C293-1 C294-2 C295-2 # FPGA_1V8 NET 'GROUND' C293-2 C294-1 C295-1 # 1 uFd, 2.2 uFd, and 22 uFd Ceramic # # 2V5 Power to the FPGA/CPU and to the DDR4 Memory # -------------------------------------------------- # # Analog_2V5 for: FPGA_PLL_2V5, XCVR_PLL_2V5, & XCVR_CLK Supplies L104: # Bulk_2V5 Power Into Filter NET 'BULK_2V5' L104-2 NET 'BULK_2V5' PVA104A-1 PVA104A-2 PVA104A-3 NET 'BULK_2V5' PVA104B-1 PVA104B-2 PVA104B-3 # Filtered Analog_2V5 Power NET 'Analog_2V5' L104-1 NET 'Analog_2V5' PVA104C-1 PVA104C-2 PVA104C-3 NET 'Analog_2V5' PVA104D-1 PVA104D-2 PVA104D-3 NET 'Analog_2V5' C283-1 C284-2 # FPGA Analog_2V5 330 uFd Tant NET 'GROUND' C283-2 C284-1 # and 22 uFd Ceramic NET 'Analog_2V5' C261-2 C262-1 C263-1 # FPGA Analog_2V5 under FPGA 0402 NET 'GROUND' C261-1 C262-2 C263-2 # Bypass Cap Grounds NET 'Analog_2V5' C264-1 C265-2 C266-2 # FPGA Analog_2V5 under FPGA 0402 NET 'GROUND' C264-2 C265-1 C266-1 # Bypass Cap Grounds NET 'Analog_2V5' C290-1 C291-1 C292-1 # FPGA Analog_2V5 NET 'GROUND' C290-2 C291-2 C292-2 # 1 uFd, 2.2 uFd, and 22 uFd Ceramic # Digital_2V5 for: DDR4 Memory Word-Line & Bank #9 Aux Supplies L105: # Bulk_2V5 Power Into Filter NET 'BULK_2V5' L105-2 NET 'BULK_2V5' PVA105A-1 PVA105A-2 PVA105A-3 NET 'BULK_2V5' PVA105B-1 PVA105B-2 PVA105B-3 # Filtered Digital_2V5 Power NET 'Digital_2V5' L105-1 NET 'Digital_2V5' PVA105C-1 PVA105C-2 PVA105C-3 NET 'Digital_2V5' PVA105D-1 PVA105D-2 PVA105D-3 NET 'Digital_2V5' C285-1 C286-2 # FPGA Digital_2V5 330 uFd Tant NET 'GROUND' C285-2 C286-1 # and 22 uFd Ceramic NET 'Digital_2V5' C271-1 C272-1 C273-2 C274-1 # FPGA Digital_2V5 under FPGA 0402 NET 'GROUND' C271-2 C272-2 C273-1 C274-2 # Bypass Cap Grounds NET 'Digital_2V5' C287-2 C288-1 C289-2 # FPGA Digital_2V5 NET 'GROUND' C287-1 C288-2 C289-1 # 1 uFd, 2.2 uFd, and 22 uFd Ceramic # # BANK 0 FPGA DDR4 Memory BULK_1V2: # --------------------------------------- # NET 'BULK_1V2' C201-2 C202-1 # Bank 0 22 uFd 1206 NET 'GROUND' C201-1 C202-2 # Bypass Cap Grounds NET 'BULK_1V2' C203-2 C204-2 # Bank 0 2.2 uFd 0603 NET 'GROUND' C203-1 C204-1 # Bypass Cap Grounds NET 'BULK_1V2' C205-1 C206-1 # Bank 0 220 nFd 0603 NET 'GROUND' C205-2 C206-2 # Bypass Cap Grounds NET 'BULK_1V2' C207-2 C208-2 # Bank 0 100 nFd 0603 NET 'GROUND' C207-1 C208-1 # Bypass Cap Grounds NET 'BULK_1V2' C209-1 C210-1 # Bank 0 100 nFd 0402 NET 'GROUND' C209-2 C210-2 # Bypass Cap Grounds NET 'BULK_1V2' C136-1 C137-1 C138-2 C139-1 # Bank 0 under FPGA 0402 NET 'GROUND' C136-2 C137-2 C138-1 C139-2 # Bypass Cap Grounds NET 'BULK_1V2' C140-2 C141-1 C142-1 # Bank 0 under FPGA 0402 NET 'GROUND' C140-1 C141-2 C142-2 # Bypass Cap Grounds NET 'BULK_1V2' C145-2 C146-2 # Bank 0 under FPGA 0402 NET 'GROUND' C145-1 C146-1 # 470 nFd Bypass Cap Grounds # # BANK 6 CPU DDR4 Memory BULK_1V2: # -------------------------------------- # NET 'BULK_1V2' C221-1 C222-1 # Bank 6 22 uFd 1206 NET 'GROUND' C221-2 C222-2 # Bypass Cap Grounds NET 'BULK_1V2' C223-1 C224-2 # Bank 6 2.2 uFd 0603 NET 'GROUND' C223-2 C224-1 # Bypass Cap Grounds NET 'BULK_1V2' C225-1 C226-1 # Bank 6 220 nFd 0603 NET 'GROUND' C225-2 C226-2 # Bypass Cap Grounds NET 'BULK_1V2' C227-2 C228-2 # Bank 6 100 nFd 0603 NET 'GROUND' C227-1 C228-1 # Bypass Cap Grounds NET 'BULK_1V2' C229-1 C230-1 # Bank 6 100 nFd 0402 NET 'GROUND' C229-2 C230-2 # Bypass Cap Grounds NET 'BULK_1V2' C131-2 C132-1 C133-2 C134-2 # Bank 6 under FPGA 0402 NET 'GROUND' C131-1 C132-2 C133-1 C134-1 # Bypass Cap Grounds NET 'BULK_1V2' C135-1 # Bank 6 under FPGA 0402 NET 'GROUND' C135-2 # Bypass Cap Grounds NET 'BULK_1V2' C143-1 C144-2 # Bank 6 under FPGA 0402 NET 'GROUND' C143-2 C144-1 # 470 nFd Bypass Cap Grounds # # BULK_3V3 Supply for Banks: #1, #2, #3, #5, and #7 # ------------------------------------------------------- # # BULK_3V3 Power to 5 of the FPGA's I/O Banks NET 'BULK_3V3' C186-2 C187-2 C188-2 C189-2 # BULK_3V3 under FPGA 0402 NET 'GROUND' C186-1 C187-1 C188-1 C189-1 # Bypass Caps Grounds NET 'BULK_3V3' C190-1 C191-2 C192-1 C193-2 # BULK_3V3 under FPGA 0402 NET 'GROUND' C190-2 C191-1 C192-2 C193-1 # Bypass Caps Grounds NET 'BULK_3V3' C194-2 C195-2 # BULK_3V3 under FPGA 0402 NET 'GROUND' C194-1 C195-1 # Bypass Caps Grounds NET 'BULK_3V3' C196-2 C197-2 # BULK_3V3 22 uFd Ceramic 1206 NET 'GROUND' C196-1 C197-1 # Bypass Caps Grounds NET 'BULK_3V3' C198-1 C199-1 C200-1 # BULK_3V3 2.2 uFd Ceramic 0603 NET 'GROUND' C198-2 C199-2 C200-2 # Bypass Caps Grounds