# # Almost-Full Nets # # CB_Fan PCB Nets # --------------------- # # # Original Rev. 20-Jan-2012 # Most Recent Rev. 11-Apr-2012 # # # This file is for the 8 Control Bus version of the CB-Fan card. # # This file defines the Almost-Full nets on the CB-Fan card. # These are signals flowing back to the Control H-Clk card. # # Recall that on connector J5 that carries signals back to the # H-Clk card, that the Almost_Full_2 signals and the SBC_n_Busy # signals share pins. # # The jumpers R101:R116 are used to either connect or disconnect # the Almost_Full_2 signals from these pins on J5. # Almost-Full-1 from C-Bus # ------------------------ NET 'ALMOST_FULL_1_1_DIR' J1-13 J5-1 # Control Bus No. 1 NET 'ALMOST_FULL_1_1_CMP' J1-14 J5-2 NET 'ALMOST_FULL_1_2_DIR' J2-13 J5-5 # Control Bus No. 2 NET 'ALMOST_FULL_1_2_CMP' J2-14 J5-6 NET 'ALMOST_FULL_1_3_DIR' J3-13 J5-9 # Control Bus No. 3 NET 'ALMOST_FULL_1_3_CMP' J3-14 J5-10 NET 'ALMOST_FULL_1_4_DIR' J3-29 J5-13 # Control Bus No. 4 NET 'ALMOST_FULL_1_4_CMP' J3-30 J5-14 NET 'ALMOST_FULL_1_5_DIR' J3-45 J5-17 # Control Bus No. 5 NET 'ALMOST_FULL_1_5_CMP' J3-46 J5-18 NET 'ALMOST_FULL_1_6_DIR' J4-13 J5-21 # Control Bus No. 6 NET 'ALMOST_FULL_1_6_CMP' J4-14 J5-22 NET 'ALMOST_FULL_1_7_DIR' J4-29 J5-25 # Control Bus No. 7 NET 'ALMOST_FULL_1_7_CMP' J4-30 J5-26 NET 'ALMOST_FULL_1_8_DIR' J4-45 J5-29 # Control Bus No. 8 NET 'ALMOST_FULL_1_8_CMP' J4-46 J5-30 # Almost-Full-2 from C-Bus # ------------------------ NET 'ALMOST_FULL_2_1_DIR' J1-15 R114-1 # Control Bus No. 1 NET 'ALMOST_FULL_2_1_CMP' J1-16 R113-1 # Almost Full 2 NET 'AMF_2_1_SBC_1_BZ_DIR' R114-2 J5-3 # Almost Full 2 CB 1 or NET 'AMF_2_1_SBC_1_BZ_CMP' R113-2 J5-4 # SBC 1 Busy NET 'ALMOST_FULL_2_2_DIR' J2-15 R116-1 # Control Bus No. 2 NET 'ALMOST_FULL_2_2_CMP' J2-16 R115-1 # Almost Full 2 NET 'AMF_2_2_SBC_2_BZ_DIR' R116-2 J5-7 # Almost Full 2 CB 2 or NET 'AMF_2_2_SBC_2_BZ_CMP' R115-2 J5-8 # SBC 2 Busy NET 'ALMOST_FULL_2_3_DIR' J3-15 R101-2 # Control Bus No. 3 NET 'ALMOST_FULL_2_3_CMP' J3-16 R102-2 # Almost Full 2 NET 'AMF_2_3_SBC_3_BZ_DIR' R101-1 J5-11 # Almost Full 2 CB 3 or NET 'AMF_2_3_SBC_3_BZ_CMP' R102-1 J5-12 # SBC 3 Busy NET 'ALMOST_FULL_2_4_DIR' J3-31 R103-2 # Control Bus No. 4 NET 'ALMOST_FULL_2_4_CMP' J3-32 R104-2 # Almost Full 2 NET 'AMF_2_4_SBC_4_BZ_DIR' R103-1 J5-15 # Almost Full 2 CB 4 or NET 'AMF_2_4_SBC_4_BZ_CMP' R104-1 J5-16 # SBC 4 Busy NET 'ALMOST_FULL_2_5_DIR' J3-47 R105-2 # Control Bus No. 5 NET 'ALMOST_FULL_2_5_CMP' J3-48 R106-2 # Almost Full 2 NET 'AMF_2_5_SBC_5_BZ_DIR' R105-1 J5-19 # Almost Full 2 CB 5 or NET 'AMF_2_5_SBC_5_BZ_CMP' R106-1 J5-20 # SBC 5 Busy NET 'ALMOST_FULL_2_6_DIR' J4-15 R107-2 # Control Bus No. 6 NET 'ALMOST_FULL_2_6_CMP' J4-16 R108-2 # Almost Full 2 NET 'AMF_2_6_SBC_6_BZ_DIR' R107-1 J5-23 # Almost Full 2 CB 6 or NET 'AMF_2_6_SBC_6_BZ_CMP' R108-1 J5-24 # SBC 6 Busy NET 'ALMOST_FULL_2_7_DIR' J4-31 R109-2 # Control Bus No. 7 NET 'ALMOST_FULL_2_7_CMP' J4-32 R110-2 # Almost Full 2 NET 'AMF_2_7_SBC_7_BZ_DIR' R109-1 J5-27 # Almost Full 2 CB 7 or NET 'AMF_2_7_SBC_7_BZ_CMP' R110-1 J5-28 # SBC 7 Busy NET 'ALMOST_FULL_2_8_DIR' J4-47 R111-2 # Control Bus No. 8 NET 'ALMOST_FULL_2_8_CMP' J4-48 R112-2 # Almost Full 2 NET 'AMF_2_8_SBC_8_BZ_DIR' R111-1 J5-31 # Almost Full 2 CB 8 or NET 'AMF_2_8_SBC_8_BZ_CMP' R112-1 J5-32 # SBC 8 Busy # Note that pins 33 & 34 of J5 bring the 40 MHz clock signal # from the Control H-Clk card to the CB-Fan card. # # Almost Full Signals from the Scaler Control Bus on J8 # NET 'FULL_1_SCLR_OR_GPIN_1_DIR' J8-13 J7-1 # Scaler Control Bus NET 'FULL_1_SCLR_OR_GPIN_1_CMP' J8-14 J7-2 NET 'FULL_2_SCLR_OR_GPIN_2_DIR' J8-15 J7-3 # Scaler Control Bus NET 'FULL_2_SCLR_OR_GPIN_2_CMP' J8-16 J7-4