# # CB_Fan PCB Nets # # Drive the J8 Scaler Connector Control Signals # ---------------======---------------------------- # # # Original Rev. 23-Feb-2012 # Most Recent Rev. 13-Apr-2012 # # # This file is for the 8 Control Bus version of the CB-Fan card. # # # J8 is the connector for Scaler Control Bus. # # This is an ECL Control Bus that uses Load_Next_Event # signal from J6 instead of the TRIG signal. # # This section of the CB-Fan net list drives the 4 Control # Signals: CRST, LNE, CLR, and CLK on to the J8 Scaler # Control Bus connector. # Drive CRST on the Scaler Control Bus the J8 Connector # The CRST signal can be sent to the Scaler Control Bus by installing R132 # The CRST signal can be held LOW on the Scaler Control Bus by installing R133 NET 'CRST_9_DIST_DIR' U41-8 # CRST Distribute 9 Direct NET 'CRST_9_DIST_CMP' U41-7 # CRST Distribute 9 Complement NET 'CRST_9_CMOS' R132-2 U41-2 # Output from CRST 9 LVDS Rec. NET 'CRST_9_ECL' U43-19 R132-1 R133-2 # Input to CRST 9 ECL Driver NET 'CRST_9_ECL_OUT_DIR' U43-24 J8-1 R81-2 # CRST DIR Out Scaler NET 'CRST_9_ECL_OUT_CMP' U43-25 J8-2 R82-1 # CRST CMP Out Scaler NET 'GROUND' R133-1 # Pull-Down for CRST # Drive LNE Load_Next_Event on the Scaler Control Bus the J8 Connector # # Recall that the LNE signal is also used for # the SBCs_READ_NOW control signal. NET 'LNE_RN_DIST_DIR' J6-7 U41-6 # LNE from J6 conn Direct NET 'LNE_RN_DIST_CMP' J6-8 U41-5 # LNE from J6 conn Complement NET 'LNE_READ_NOW_CMOS_ECL' U43-20 U41-3 # LNE Dist CMOS to ECL NET 'LNE_ECL_OUT_DIR' U43-27 J8-3 R83-2 # LNE DIR Out Scaler NET 'LNE_ECL_OUT_CMP' U43-26 J8-4 R84-1 # LNE CMP Out Scaler # Drive CLR on the Scaler Control Bus the J8 Connector # The CLR signal can be sent to the Scaler Control Bus by installing R134 # The CLR signal can be held LOW on the Scaler Control Bus by installing R135 NET 'CLR_9_DIST_DIR' U42-8 # CLR Distribute 9 Direct NET 'CLR_9_DIST_CMP' U42-7 # CLR Distribute 9 Complement NET 'CLR_9_CMOS' R134-2 U42-2 # Output from CLR 9 LVDS Rec. NET 'CLR_9_ECL' U43-13 R134-1 R135-2 # Input to CLR 9 ECL Driver NET 'CLR_9_ECL_OUT_DIR' U43-4 J8-5 R85-2 # CLR DIR Out Scaler NET 'CLR_9_ECL_OUT_CMP' U43-5 J8-6 R86-1 # CLR CMP Out Scaler NET 'GROUND' R135-1 # Pull-Down for CRST # Drive CLK on the Scaler Control Bus the J8 Connector NET 'CLK_9_DIST_DIR' U42-6 # CLK Distribute 9 Direct NET 'CLK_9_DIST_CMP' U42-5 # CLK Distribute 9 Complement NET 'CLK_9_CMOS_ECL' U43-12 U42-3 # CLK Dist 9 CMOS to ECL NET 'CLK_9_ECL_OUT_DIR' U43-7 J8-7 R87-2 # CLK DIR Out Scaler NET 'CLK_9_ECL_OUT_CMP' U43-6 J8-8 R88-1 # CLK CMP Out Scaler # Ground the 2 unused inputs to the ECL Driver chip U43 NET 'GROUND' U43-11 U43-18 # Connect the ECL Pull Down Resistors to the Vtt Supply NET 'VTT_1' R81-1 R82-2 NET 'VTT_1' R83-1 R84-2 NET 'VTT_1' R85-1 R86-2 NET 'VTT_1' R87-1 R88-2