# This is a Key In Net List file for # the H-CLK card for HAWC # VME Backplane P1 Connector # --------------====---------- # # Original Rev. 21-Apr-2011 # Most Recent Rev. 7-Nov-2011 # This file includes all the nets from the VME "P1" connector # including the "Z" and "D" columns of this connector. In this # file there is a separate "statement" for each of the 160 # pins in this connector. Only the pins in this connector that # have signals that are used in the H-CLK design have Mentor # Graphics NET statements. # The "Z" Column # -------------- # pin P1-Z1 is VME-64X signal MPR MTM-Bus Pause Request NET 'GROUND' P1-Z2 # VME-64X ground pin # pin P1-Z3 is VME-64X signal MCLK MTM-Bus Clock NET 'GROUND' P1-Z4 # VME-64X ground pin # pin P1-Z5 is VME-64X signal MSD MTM-Bus Slave Data NET 'GROUND' P1-Z6 # VME-64X ground pin # pin P1-Z7 is VME-64X signal MMD MTM-Bus Master Data NET 'GROUND' P1-Z8 # VME-64X ground pin # pin P1-Z9 is VME-64X signal MCTC MTM-Bus Control NET 'GROUND' P1-Z10 # VME-64X ground pin # pin P1-Z11 is VME-64X signal RESP* 2eVME protocol Response NET 'GROUND' P1-Z12 # VME-64X ground pin # pin P1-Z13 is VME-64X Reserved Bus signal 0 NET 'GROUND' P1-Z14 # VME-64X ground pin # pin P1-Z15 is VME-64X Reserved Bus signal 1 NET 'GROUND' P1-Z16 # VME-64X ground pin # pin P1-Z17 # VME-64X Reserved Bus signal 2 NET 'GROUND' P1-Z18 # VME-64X ground pin # pin P1-Z19 # VME-64X Reserved Bus signal 3 NET 'GROUND' P1-Z20 # VME-64X ground pin # pin P1-Z21 # VME-64X Reserved Bus signal 4 NET 'GROUND' P1-Z22 # VME-64X ground pin # pin P1-Z23 # VME-64X Reserved Bus signal 5 NET 'GROUND' P1-Z24 # VME-64X ground pin # pin P1-Z25 # VME-64X Reserved Bus signal 6 NET 'GROUND' P1-Z26 # VME-64X ground pin # pin P1-Z27 # VME-64X Reserved Bus signal 7 NET 'GROUND' P1-Z28 # VME-64X ground pin # pin P1-Z29 # VME-64X Reserved Bus signal 8 NET 'GROUND' P1-Z30 # VME-64X ground pin # pin P1-Z31 # VME-64X Reserved Bus signal 9 NET 'GROUND' P1-Z32 # VME-64X ground pin # The "A" Column # -------------- NET 'VME_DATA(0)' P1-A1 # VME Data Bus D00 NET 'VME_DATA(1)' P1-A2 # VME Data Bus D01 NET 'VME_DATA(2)' P1-A3 # VME Data Bus D02 NET 'VME_DATA(3)' P1-A4 # VME Data Bus D03 NET 'VME_DATA(4)' P1-A5 # VME Data Bus D04 NET 'VME_DATA(5)' P1-A6 # VME Data Bus D05 NET 'VME_DATA(6)' P1-A7 # VME Data Bus D06 NET 'VME_DATA(7)' P1-A8 # VME Data Bus D07 NET 'GROUND' P1-A9 # VME ground pin # pin P1-A10 # VME System_Clock 'VME_SYSCLK' NET 'GROUND' P1-A11 # VME ground pin NET 'VME_DS1_B' P1-A12 # VME Data_Strobe_1_* # pin P1-A13 # VME Data_Strobe_0_* 'VME_DS0_B' NET 'VME_WRITE_B' P1-A14 # VME Write_* NET 'GROUND' P1-A15 # VME ground pin NET 'VME_DTACK_B' P1-A16 # VME Data_Transfer_Acknowledge_* NET 'GROUND' P1-A17 # VME ground pin NET 'VME_AS_B' P1-A18 # VME Address_Strobe_* NET 'GROUND' P1-A19 # VME ground pin NET 'VME_IACK_B' P1-A20 # VME Interrupt_Acknowledge_* NET 'VME_IACK_LOOP' P1-A21 # VME Interrupt_Acknowledge_In_* 'VME_IACKIN_B' NET 'VME_IACK_LOOP' P1-A22 # VME Interrupt_Acknowledge_Out_* 'VME_IACKOUT_B' NET 'VME_AM(4)' P1-A23 # VME Address Modifier 4 NET 'VME_ADDR(7)' P1-A24 # VME Address Bus A07 NET 'VME_ADDR(6)' P1-A25 # VME Address Bus A06 NET 'VME_ADDR(5)' P1-A26 # VME Address Bus A05 NET 'VME_ADDR(4)' P1-A27 # VME Address Bus A04 NET 'VME_ADDR(3)' P1-A28 # VME Address Bus A03 NET 'VME_ADDR(2)' P1-A29 # VME Address Bus A02 NET 'VME_ADDR(1)' P1-A30 # VME Address Bus A01 NET 'VME_N12V' P1-A31 # VME -12 Volt Bus Power NET 'VME_5V' P1-A32 # VME +5 Volt Bus Power # The "B" Column # -------------- # pin P1-B1 VME Bus_Busy_* signal 'VME_BBSY_B' # pin P1-B2 VME Bus_Clear_* signal 'VME_BCLR_B' # pin P1-B3 VME AC_Power_Fail_* signal 'VME_ACFAIL_B' # Note that the Bus Grant In-Out pin pairs # are just tied together. NET 'BUS_GRANT_0' P1-B4 P1-B5 # P1-B4 is VME Bus_Grant_0_In_* signal # P1-B5 is VME Bus_Grant_0_Out_* signal NET 'BUS_GRANT_1' P1-B6 P1-B7 # P1-B6 is VME Bus_Grant_1_In_* signal # P1-B7 is VME Bus_Grant_1_Out_* signal NET 'BUS_GRANT_2' P1-B8 P1-B9 # P1-B8 is VME Bus_Grant_2_In_* signal # P1-B9 is VME Bus_Grant_2_Out_* signal NET 'BUS_GRANT_3' P1-B10 P1-B11 # P1-B10 is VME Bus_Grant_3_In_* signal # P1-B11 is VME Bus_Grant_3_Out_* signal # pin P1-B12 VME Bus_Request_0_* signal 'VME_BR_B(0)' # pin P1-B13 VME Bus_Request_1_* signal 'VME_BR_B(1)' # pin P1-B14 VME Bus_Request_2_* signal 'VME_BR_B(2)' # pin P1-B15 VME Bus_Request_3_* signal 'VME_BR_B(3)' NET 'VME_AM(0)' P1-B16 # VME Address Modifier 0 NET 'VME_AM(1)' P1-B17 # VME Address Modifier 1 NET 'VME_AM(2)' P1-B18 # VME Address Modifier 2 NET 'VME_AM(3)' P1-B19 # VME Address Modifier 3 NET 'GROUND' P1-B20 # VME ground pin # pin P1-B21 VME Serial Clock 'VME_SERCLK' # pin P1-B22 VME Serial Data 'VME_SERDAT' NET 'GROUND' P1-B23 # VME ground pin # pin P1-B24 VME IRQ7* 'VME_IRQ_B(7)' # pin P1-B25 VME IRQ6* 'VME_IRQ_B(6)' # pin P1-B26 VME IRQ5* 'VME_IRQ_B(5)' # pin P1-B27 VME IRQ4* 'VME_IRQ_B(4)' # pin P1-B28 VME IRQ3* 'VME_IRQ_B(3)' # pin P1-B29 VME IRQ2* 'VME_IRQ_B(2)' # pin P1-B30 VME IRQ1* 'VME_IRQ_B(1)' # pin P1-B31 VME +5 Volt Standby NET 'VME_5V' P1-B32 # VME +5 Volt Bus Power # The "C" Column # -------------- NET 'VME_DATA(8)' P1-C1 # VME Data Bus D08 NET 'VME_DATA(9)' P1-C2 # VME Data Bus D09 NET 'VME_DATA(10)' P1-C3 # VME Data Bus D10 NET 'VME_DATA(11)' P1-C4 # VME Data Bus D11 NET 'VME_DATA(12)' P1-C5 # VME Data Bus D12 NET 'VME_DATA(13)' P1-C6 # VME Data Bus D13 NET 'VME_DATA(14)' P1-C7 # VME Data Bus D14 NET 'VME_DATA(15)' P1-C8 # VME Data Bus D15 NET 'GROUND' P1-C9 # VME ground pin # pin P1-C10 # VME System_Fail_* signal 'VME_SYSFAIL_B' # pin P1-C11 # VME Bus_Error_* signal 'VME_BERR_B' NET 'VME_SYSRESET_B' P1-C12 # VME System_Reset_* signal # pin P1-C13 # VME Long_Word signal 'VME_LWORD_B' NET 'VME_AM(5)' P1-C14 # VME Address Modifier 5 NET 'VME_ADDR(23)' P1-C15 # VME Address Bus A23 NET 'VME_ADDR(22)' P1-C16 # VME Address Bus A22 NET 'VME_ADDR(21)' P1-C17 # VME Address Bus A21 NET 'VME_ADDR(20)' P1-C18 # VME Address Bus A20 NET 'VME_ADDR(19)' P1-C19 # VME Address Bus A19 NET 'VME_ADDR(18)' P1-C20 # VME Address Bus A18 NET 'VME_ADDR(17)' P1-C21 # VME Address Bus A17 NET 'VME_ADDR(16)' P1-C22 # VME Address Bus A16 NET 'VME_ADDR(15)' P1-C23 # VME Address Bus A15 NET 'VME_ADDR(14)' P1-C24 # VME Address Bus A14 NET 'VME_ADDR(13)' P1-C25 # VME Address Bus A13 NET 'VME_ADDR(12)' P1-C26 # VME Address Bus A12 NET 'VME_ADDR(11)' P1-C27 # VME Address Bus A11 NET 'VME_ADDR(10)' P1-C28 # VME Address Bus A10 NET 'VME_ADDR(9)' P1-C29 # VME Address Bus A09 NET 'VME_ADDR(8)' P1-C30 # VME Address Bus A08 NET 'VME_P12V' P1-C31 # VME +12 Volt Bus Power NET 'VME_5V' P1-C32 # VME +5 Volt Bus Power # The "D" Column # -------------- # pin P1-D1 is VME-64X signal VPC(1) Voltage PreCharge NET 'GROUND' P1-D2 # VME-64X ground pin Extended Pin # pin P1-D3 is VME-64X +V1 + side of 48 Volt Power # pin P1-D4 is VME-64X +V2 + side of 48 Volt Power # pin P1-D5 is VME-64X Reserved UnBused # pin P1-D6 is VME-64X -V1 - side of 48 Volt Power # pin P1-D7 is VME-64X -V2 - side of 48 Volt Power # pin P1-D8 is VME-64X Reserved UnBused # pin P1-D9 is VME-64X Geographic Address Parity NET 'VME_GEO_B(0)' P1-D10 # VME-64X Geographic Adress (0) bar NET 'VME_GEO_B(1)' P1-D11 # VME-64X Geographic Adress (1) bar NET 'VDD_LOGIC' P1-D12 # VME-64X +3.3 Volt Bus Power NET 'VME_GEO_B(2)' P1-D13 # VME-64X Geographic Adress (2) bar NET 'VDD_LOGIC' P1-D14 # VME-64X +3.3 Volt Bus Power NET 'VME_GEO_B(3)' P1-D15 # VME-64X Geographic Adress (3) bar NET 'VDD_LOGIC' P1-D16 # VME-64X +3.3 Volt Bus Power NET 'VME_GEO_B(4)' P1-D17 # VME-64X Geographic Adress (4) bar NET 'VDD_LOGIC' P1-D18 # VME-64X +3.3 Volt Bus Power # pin P1-D19 # VME-64X Reserved Bus signal 10 NET 'VDD_LOGIC' P1-D20 # VME-64X +3.3 Volt Bus Power # pin P1-D21 # VME-64X Reserved Bus signal 11 NET 'VDD_LOGIC' P1-D22 # VME-64X +3.3 Volt Bus Power # pin P1-D23 # VME-64X Reserved Bus signal 12 NET 'VDD_LOGIC' P1-D24 # VME-64X +3.3 Volt Bus Power # pin P1-D25 # VME-64X Reserved Bus signal 13 NET 'VDD_LOGIC' P1-D26 # VME-64X +3.3 Volt Bus Power # pin P1-D27 is VME-64X signal LI/I* Live Insertion Input NET 'VDD_LOGIC' P1-D28 # VME-64X +3.3 Volt Bus Power # pin P1-D29 is VME-64X signal LI/O* Live Insertion Output NET 'VDD_LOGIC' P1-D30 # VME-64X +3.3 Volt Bus Power NET 'GROUND' P1-D31 # VME-64X ground pin Extended Pin # pin P1-D32 is VME-64X signal VPC(1) Voltage PreCharge