Optical Link Current Source --------------------------- Rev. 17-APR-1993 Controls Indicators Connectors ------------------------------------------- Analog Section -------------- Controls: Analog Section On/Off, Current Range, Current Zero Indicators: Meter Percent of Full Scale Output, LED's Power On Connections: +-12 Volt to +-15 Volt Analog Power Supply Connection, 4 Optic Cable Connections, Output Current Connection Digital Section --------------- Controls: Power On/Off, Push to Sweep, Manual Sweep Toggle Switch, Internal-External Load Toggle Switch, Sweep Rate 3 Section Lever Wheel Switch, Target Code Source Select Toggle Switch, Fixed Target Codes 8 Toggle Switches, Variable Target Codes 5 Lever Wheel Switches Indicators: Power ON LED, Output Stable LED, 5 Hex LED Output Code Display Connections: AC Mains Power Input, 4 Optic Cable Connectors Mains Power Selector: Side 1 100 Volts A-B, C-D, E-F 220 Volts A-B, C, D-E, F Side 2 120 Volts A, B-C-D, E-F 240 Volts A, B-C, D-E, F