LIST OF BAD FIBERS/TILES FOR ANL011
 

QC 6 VERSION 5.2

First LED Scan: : July 24-00

 

PMT

LAYER

CELL

TILE

SLOT

%DEV

PROBLEM - SOLUTION

             

5

7

C10-O

1

12

-42.7

SPECIAL TILE

12

2

A13-E

21

47

-36.0

No problem found

17

8

D5-O

39

56

-27.4

No problem found

17

11

D5-O

1

18*

-39.2

Profile loose - inserted more shim and reseated

18

8

D5-E

46

63

-27.4

No problem found

18

10

D5-E

22

39

-25.5

No problem found

23

7

B13-O

22

82*

-28.0

Profile loose - reseated

24

6

B13-E

13

73

-46.9

Resseated Profile

24

6

B13-E

15

75

-38.9

Reseated Profile

33

5

B14-O

3

93

-25.8

No problem found

33

7

B14-O

3

93

-25.8

No problem found

34

5

B14-E

4

94

-42.6

Profile loose - reseated

37

11

D6-O

16

98*

-29.3

Added shim - reseated profile

37

11

D6-O

18

100

-36.2

Fiber not centered in profile - reseated

38

11

D6-E

65

147

-38.6

Fiber partly on side of tile - fixed

43

5

B15-O

18

140

-30.2

Reseated profile

43

7

B15-O

18

140

-28.6

Reseated Profile

 

 

Final Scan: July 27, 2000

 

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

5

7

C10-O

1

12

-42.7

 

12

2

A13-E

21

47

-33.4

 

17

8

D5-O

39

56

-27.4

 

18

8

D5-E

46

63

-27.4

 

18

10

D5-E

22

39

-25.5

 

23

7

B13-O

22

82*

-28.0

 

33

5

B14-O

3

93

-30.8

 

33

7

B14-O

3

93

-25.8

 

34

5

B14-E

11

101

-27.2

 

37

11

D6-O

16

98*

-33.9

 

37

11

D6-O

18

100

-33.2

 

43

5

B15-O

18

140

-32.3

 

43

7

B15-O

18

140

-28.6

 

 

This information is in the process of being transcribed from the logbook.