* QC 6 VERSION 5.2:

LIST OF BAD FIBERS/TILES FOR ANL014

Initial scan Aug. 29, 2000

 

PMT

Layer

Cell-Side

Tile *

Slot

% Dev

Problem/Solution

5

7

C10-O

1

12

-32.1

Special Tile

5

7

C10-O

2

13

-32.3

 

6

7

C10-E

1

12

-39.8

Special Tiles

6

8

C10-E

1

12

-28.1

6

9

C10-E

1

12

-36.7

8

2

A12-E

9

26

-59.2

Fiber kinked at exit of profile - replaced

11

1

A13-O

8

34*

-67.8

Wide gap, profile loose - reseated and taped

12

1

A13-E

10

36

-29.7

Profile - weld bead interference at top of slot - repositioned

15

4

B12-O

16

49

-35.8

Narrow slot - profile & fiber look OK - replaced fiber anyway

15

6

B12-O

16

49

-35.4

15

7

B12-O

2

35

-27.8

Wide slot - reseated profile

16

7

B12-E

2

35

-28.7

17

11

D5-O

31

48

-26.4

Looks OK - reseated profile

18

9

D5-E

20

37

-37.5

Looks OK - reseated profile

29

5

A15-O

17

96

MISROUTED

This fiber was misrouted from B14 It was found in previous QC and was reported to have been fixed. We fixed it now.

29

7

A15-O

17

96

MISROUTED

30

2

A15-E

1

80

-27.4

These look OK - reseated profiles

30

2

A15-E

23

102

-26.0

33

4

B14-O

32

122

-25.3

33

5

B14-O

17

107

MISSING

See comment for A15 above

33

7

B14-O

17

107

MISSING

34

4

B14-E

12

102

-29.2

This is a fiber that had been previously replaced

34

4

B14-E

29

119

-35.8

Fiber looked OK

34

6

B14-E

12

102

-30.7

This is a fiber that had been previously replaced

34

6

B14-E

29

119

-28.7

Fiber looked OK

37

11

D6-O

31

113

-25.5

Reseated profile

37

11

D6-O

66

148

MISSING

On side of tile - fixed

37

11

D6-O

70

152

-27.7

Wide slot-Reseated profile

37

11

D6-O

75

157

-34.0

Loose prfile - Reseated profile

38

8

D6-E

20

102

-42.0

These fibers appear to have badly polished ends - we repolished this aspirin tube

38

8

D6-E

23

105

-29.6

38

8

D6-E

25

107

-27.9

38

8

D6-E

26

108

-39.2

38

8

D6-E

29

111

-39.8

38

8

D6-E

71

153

-28.2

38

9

D6-E

9

91

-50.4

38

10

D6-E

20

102

-38.2

38

10

D6-E

23

105

-28.7

38

10

D6-E

25

107

-27.1

38

10

D6-E

26

108

-36.6

38

10

D6-E

29

111

-36.3

38

11

D6-E

9

91

-47.5

38

11

D6-E

31

113

-28.0

38

11

D6-E

61

143

-26.5

38

11

D6-E

67

149

-25.1

41

1

A16-O

34

143

-26.4

Reseated profile

42

1

A16-E

33

142*

-33.7

Wide slot - added shim

42

1

A16-E

47

156

-27.9

Wide slot - Reseated profile

42

3

A16-E

33

142*

MISSING

On side of tile - fixed

42

3

A16-E

47

156

-25.5

Wdie slot - Reseated profile

44

4

B15-E

9

131

-27.2

Reseated profile

 

 

FINAL SCAN: Sept. 15

 

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

4

11

D4-E

4

4

-29.5

 

5

7

C10-O

2

13

-42.9

 

6

7

C10-E

1

12

-41.1

Special tiles

 

 

6

8

C10-E

1

12

-25.6

6

9

C10-E

1

12

-39.7

15

6

B12-O

19

52

-25.2

 

15

7

B12-O

2

35

-26.1

 

 

16

7

B12-E

2

35

-30.4

29

2

A15-O

6

85

-26.0

 

30

2

A15-E

1

80

-35.4

 

30

3

A15-E

19

98*

-29.5

 

34

4

B14-E

12

102

-28.3

 

34

4

B14-E

29

119

-29.6

 

34

6

B14-E

12

102

-31.0

 

34

6

B14-E

29

119

-28.1

 

37

9

D6-O

42

124

-33.0

 

37

11

D6-O

70

152

-26.6

 

38

11

D6-E

31

113

-26.3

 

38

11

D6-E

61

143

-30.3

 

38

11

D6-E

67

149

-28.3

 

42

1

A16-E

33

142*

-25.9

 

44

4

B15-E

9

131

-25.2