QC 6 VERSION 5.6: 7-Jun-01 09:19:38

LIST OF FIBERS/TILES WITH RESPONSE < 80% FOR ANL028, SCAN A

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-32.5

Special Tiles

4

10

D4-E

1

1

-36.3

5

7

C10-O

1

12

-30.2

5

8

C10-O

1

12

-25.5

5

9

C10-O

1

12

-27.4

6

7

C10-E

1

12

-29.2

6

8

C10-E

1

12

-22.2

9

7

B11-O

1

18*

-75.7

Wide Slot - added shim & reseated profile

12

1

A13-E

4

30

-32.3

Fiber replaced

12

2

A13-E

12

38

-47.7

Fiber replaced

12

2

A13-E

13

39

-38.3

Fiber replaced

12

3

A13-E

4

30

-32.6

Fiber replaced

12

3

A13-E

10

36

-83.7

On side of tile -fixed

15

7

B12-O

1

34*

-39.9

On side of tile -fixed

16

5

B12-E

12

45

-44.4

Fiber replaced

16

7

B12-E

12

45

-44.4

18

10

D5-E

63

80

-58.8

On side of tile -fixed

21

3

A14-O

21

72

-68.0

On side of tile -fixed

22

1

A14-E

27

78

-27.5

Fiber replaced

22

3

A14-E

8

59

-78.3

On side of tile -fixed

22

3

A14-E

27

78

-28.5

Fiber replaced

23

4

B13-O

5

65

-23.5

Wide slots - re-centered fibers on tiles and reseated profiles

23

4

B13-O

18

78

-27.2

23

4

B13-O

25

85

-34.9

23

4

B13-O

27

87

-47.0

23

6

B13-O

15

75

-35.6

Fiber not in contact with tile - reseated

29

1

A15-O

3

82*

-34.4

Fiber replaced

29

2

A15-O

24

103

-42.1

Fiber replaced

29

3

A15-O

3

82*

-31.1

Fiber replaced

29

3

A15-O

13

92

-58.1

On side of tile -fixed

33

4

B14-O

7

97

-62.9

On side of tile and detached from porfile-fixed

33

4

B14-O

9

99

-31.2

Wide slots - re-centered fibers on tiles and reseated profiles

33

4

B14-O

10

100

-56.9

33

4

B14-O

18

108

-35.7

34

6

B14-E

31

121

-26.8

37

11

D6-O

75:75

157

MISSING

Problem with source

38

8

D6-E

32

114*

-60.2

On side of tile and detached from porfile-fixed

38

9

D6-E

6

88

-55.7

Masking paint smeared on tile - cleaned

38

9

D6-E

7

89

-21.6

Marginal fiber - not replaced

38

9

D6-E

57

139

-88.7

Fiber detached from profile - fixed

38

11

D6-E

7

89

-22.6

Marginal fiber - not replaced

38

11

D6-E

75:75

157

MISSING

Problem with source

43

7

B15-O

20

142*

-35.0

On side of tile -fixed

43

7

B15-O

25

147

-22.5

Reseated profile

 

 

QC 6 VERSION 5.6: 07-Jun-01 16:43:37

LIST OF FIBERS/TILES WITH RESPONSE < 75% FOR ANL028 SCAN B

 

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-29.6

Special Tiles

4

10

D4-E

1

1

-29.7

5

7

C10-O

1

12

-32.0

5

8

C10-O

1

12

-25.9

5

9

C10-O

1

12

-28.1

6

7

C10-E

1

12

-27.9

23

4

B13-O

27

87

-52.3

Fiber on side of tile - shimmed slot & reseated profile

33

4

B14-O

10

100

-46.8

New problem - fiber replaced

33

4

B14-O

16

106

-54.5

New problem - fiber replaced

33

5

B14-O

15

105

-27.3

New problem -no practical fix

33

5

B14-O

16

106

-47.3

New problem - fiber replaced

33

6

B14-O

10

100

-40.1

New problem - fiber replaced

33

6

B14-O

16

106

-55.8

New problem - fiber replaced

33

7

B14-O

15

105

-27.5

New problem - no practical fix

33

7

B14-O

16

106

-46.2

New problem - fiber replaced

34

6

B14-E

31

121

-25.0

No obvious problem

38

9

D6-E

6

88

-53.1

Fiber detached from profile - fixed

 

 

QC 6 VERSION 5.6: 13-Jun-01 08:57:40

LIST OF FIBERS/TILES WITH RESPONSE < 75% FOR ANL028 SCAN C

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-29.6

Special Tiles

4

10

D4-E

1

1

-29.7

5

7

C10-O

1

12

-31.0

5

8

C10-O

1

12

-25.9

5

9

C10-O

1

12

-26.7

6

7

C10-E

1

12

-28.8

33

5

B14-O

15

105

-26.0

No practical fix available - no teflon inserts left

33

7

B14-O

15

105

-26.3