QC 6 VERSION 5.8: 19-Jul-01 09:15:28
LIST OF FIBERS/TILES WITH RESPONSE < 75%
FOR ANL034 Scan A
PMT |
LAYER |
CELL |
TILE |
SLOT |
%DEV |
SOLUTION |
5 |
2 |
C10-O |
147 |
158 |
MISROUTED |
No, pedestal shift |
5 |
8 |
C10-O |
1 |
12 |
-34.7 |
Special tiles |
6 |
8 |
C10-E |
1 |
12 |
-44.7 |
|
9 |
5 |
B11-O |
12 |
29 |
-26.0 |
Replaced fiber |
9 |
7 |
B11-O |
12 |
29 |
-22.8 |
|
10 |
5 |
B11-E |
6 |
23 |
-37.7 |
Replaced fiber |
10 |
7 |
B11-E |
6 |
23 |
-37.3 |
|
11 |
1 |
A13-O |
18 |
44 |
-37.3 |
Replaced fiber |
11 |
3 |
A13-O |
18 |
44 |
-38.0 |
|
11 |
2 |
A13-O |
2 |
28 |
-40.7 |
Replaced fiber |
11 |
3 |
A13-O |
23 |
49 |
-39.5 |
On side of tile - fixed |
15 |
7 |
B12-O |
11 |
44 |
-70.4 |
On side of tile, unglued - fixed |
15 |
7 |
B12-O |
15 |
48 |
-38.4 |
On side of tile - fixed |
15 |
7 |
B12-O |
20 |
53 |
-32.5 |
On side of tile - fixed |
15 |
7 |
B12-O |
21 |
54 |
-31.7 |
On side of tile - fixed |
15 |
7 |
B12-O |
23 |
56 |
-29.0 |
On side of tile - fixed |
15 |
7 |
B12-O |
24 |
57 |
-58.1 |
On side of tile - fixed |
16 |
7 |
B12-E |
8 |
41 |
-32.1 |
On side of tile - fixed |
17 |
11 |
D5-O |
21 |
38 |
-33.7 |
Profile not in - reseated |
18 |
10 |
D5-E |
65 |
82* |
-76.2 |
On side of tile - fixed |
21 |
2 |
A14-O |
25 |
76 |
-54.8 |
On side of tile - fixed |
23 |
4 |
B13-O |
30 |
90 |
-28.3 |
Replaced fiber |
23 |
6 |
B13-O |
30 |
90 |
-22.2 |
|
24 |
7 |
B13-E |
3 |
63 |
-27.5 |
Loose profile - reseated |
29 |
1 |
A15-O |
3 |
82* |
-33.7 |
Bad slot - replaced shim |
29 |
3 |
A15-O |
3 |
82* |
-21.2 |
|
29 |
2 |
A15-O |
14 |
93 |
-27.1 |
Replaced fiber |
33 |
4 |
B14-O |
8 |
98* |
-33.7 |
On side of tile - fixed |
37 |
8 |
D6-O |
8 |
90 |
-31.1 |
Replaced fiber |
37 |
10 |
D6-O |
8 |
90 |
-30.5 |
|
37 |
8 |
D6-O |
26 |
108 |
-48.4 |
Replaced fiber |
37 |
10 |
D6-O |
26 |
108 |
-43.5 |
|
37 |
10 |
D6-O |
17 |
99 |
-25.6 |
Replaced tiles |
37 |
10 |
D6-O |
18 |
100 |
-26.7 |
|
38 |
8 |
D6-E |
75 |
157 |
-31.0 |
Reeplaced fiber |
38 |
10 |
D6-E |
75 |
157 |
-25.8 |
|
38 |
10 |
D6-E |
18 |
100 |
-29.7 |
Replaced tile |
41 |
2 |
A16-O |
2 |
111 |
-29.9 |
Profile not in - fixed |
41 |
2 |
A16-O |
15 |
124 |
-34.0 |
Replaced fiber |
QC 6 VERSION 5.8: 19-Jul-01 12:50:59
LIST OF FIBERS/TILES WITH RESPONSE < 75%
FOR ANL034 Scan B
PMT |
LAYER |
CELL |
TILE |
SLOT |
%DEV |
SOLUTION |
5 |
8 |
C10-O |
1 |
12 |
-36.6 |
Special tiles |
6 |
8 |
C10-E |
1 |
12 |
-45.5 |
|
15 |
7 |
B12-O |
10 |
43 |
-27.4 |
On side of tile - fixed |
18 |
11 |
D5-E |
6 |
23 |
-28.4 |
On side of tile - fixed |
QC 6 VERSION 5.8: 20-Jul-01 12:25:50
LIST OF FIBERS/TILES WITH RESPONSE < 75%
FOR ANL034 Scan C
PMT |
LAYER |
CELL |
TILE |
SLOT |
%DEV |
SOLUTION |
5 |
8 |
C10-O |
1 |
12 |
-26.6 |
Special tiles |
6 |
8 |
C10-E |
1 |
12 |
-30.9 |
|
18 |
11 |
D5-E |
6 |
23 |
-27.0 |