QC 6 VERSION 6.0: 14-May-02 13:18:17

LIST OF FIBERS/TILES WITH RESPONSE < 80%

FOR ANL049 SCAN A

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-21.5

Special Tile

4

10

D4-E

10

10

-36.0

Replaced fiber

7

2

A12-O

4

21

-21.0

Replaced fiber

12

1

A13-E

4

30

-21.8

Hand Polished Aspirin Tube- Diamond cut not good

12

3

A13-E

4

30

-19.3

12

2

A13-E

9

35

-25.3

12

2

A13-E

21

47

-21.2

17

11

D5-O

33

50*

-20.6

Replaced fiber

18

8

D5-E

6

23

-21.2

Replaced fiber

18

10

D5-E

6

23

-16.4

18

11

D5-E

49

66*

-34.2

Add shim,Re-seated profile

22

1

A14-E

23

74

-25.3

Hand Polished Aspirin Tube- Diamond cut not good

22

3

A14-E

23

74

-16.8

22

1

A14-E

24

75

-30.9

22

3

A14-E

24

75

-22.4

22

1

A14-E

26

77

-24.9

22

3

A14-E

26

77

-20.1

22

2

A14-E

19

70

-21.5

22

2

A14-E

25

76

-25.7

22

2

A14-E

26

77

-28.8

23

4

B13-O

16

76

-20.5

Hand Polished Aspirin Tube- Diamond cut not good

23

6

B13-O

16

76

-32.9

23

4

B13-O

17

77

-25.2

23

6

B13-O

17

77

-27.1

23

6

B13-O

18

78

-20.5

23

6

B13-O

19

79

-33.4

34

4

B14-E

4

94

-35.6

Replaced fiber

34

6

B14-E

4

94

-25.4

37

8

D6-O

69

151

-25.2

Replaced fiber

37

10

D6-O

69

151

-23.9

37

9

D6-O

67

149

-21.3

Cleaned fiber

37

11

D6-O

67

149

-16.4

37

9

D6-O

73

155

-20.6

Replaced fiber

37

11

D6-O

73

155

-18.8

38

8

D6-E

55

137

-39.0

Replaced fiber

38

10

D6-E

55

137

-37.9

38

9

D6-E

67

149

-20.6

Reseated profile

38

9

D6-E

71

153

-30.9

Replaced fiber

38

11

D6-E

71

153

-26.1

41

1

A16-O

7

116

-21.5

Reseated profile

41

2

A16-O

19

128

-21.7

Reseated profile

41

2

A16-O

37

146

-27.9

Replaced fiber

41

3

A16-O

32

141

-20.8

Reseated profile

42

1

A16-E

29

138

-21.0

Replaced fiber

42

3

A16-E

29

138

-23.7

42

1

A16-E

31

140

-27.3

Replaced fiber

42

3

A16-E

31

140

-46.0

42

2

A16-E

47

156

-34.8

Replaced fiber

43

5

B15-O

15

137

-21.1

Replaced tile

43

7

B15-O

18

140

-21.3

Replaced fiber

44

5

B15-E

15

137

-67.6

Replaced tile

44

7

B15-E

32

154

-21.7

Reseated profile

44

7

B15-E

34

156

-21.1

Reseated profile

 

QC 6 VERSION 6.0: 28-May-02 12:06:30

LIST OF FIBERS/TILES WITH RESPONSE < 80%

FOR ANL049 SCAN B

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-23.6

Special Tile

4

10

D4-E

1

1

-20.3

7

2

A12-O

4

21

-48.3

Fiber replaced

12

2

A13-E

21

47

-28.5

Fiber replaced

17

8

D5-O

50

67

-20.8

These are all new problems -reseated profiles

17

10

D5-O

58

75

-20.5

17

10

D5-O

59

76

-20.3

17

11

D5-O

17

34*

-22.5

17

11

D5-O

34

51

-22.9

18

10

D5-E

65

82*

-20.2

18

11

D5-E

17

34*

-23.0

23

4

B13-O

17

77

-25.2

Fiber replaced

23

6

B13-O

17

77

-19.9

23

6

B13-O

16

76

-21.8

Reseat profile

23

6

B13-O

19

79

-23.5

Reseat profile

30

1

A15-E

19

98*

-23.4

Shimmed slot

37

10

D6-O

35

117

-20.9

Reseat profile

38

8

D6-E

7

89

-21.6

Reseat profile

38

10

D6-E

7

89

-15.8

Reseat profile

38

11

D6-E

55

137

-20.3

Reseat profile

38

11

D6-E

60

142*

-22.2

Reseat profile

38

11

D6-E

67

149

-20.5

Reseat profile

41

1

A16-O

7

116

-21.5

Reseat profile

42

1

A16-E

29

138

-35.9

Fiber replaced

42

3

A16-E

29

138

-32.3

42

1

A16-E

48

157

-49.1

Reseat profile

42

3

A16-E

11

120

-23.4

Reseat profile

44

7

B15-E

5

127

-21.7

Reseat profile

44

7

B15-E

32

154

-22.2

Reseat profile

 

QC 6 VERSION 6.0: 4-Jun-02 08:31:24

LIST OF FIBERS/TILES WITH RESPONSE < 75%

FOR ANL049 Scan C

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

22

3

A14-E

15

66*

-82.1

Profile loose - shimmed submodule gap

42

1

A16-E

29

138

-51.5

Replaced aspirin tube with modified one and inserted more spare fibers

42

3

A16-E

29

138

-46.7

 

QC 6 VERSION 6.0: 5-Jun-02 15:18:35

LIST OF FIBERS/TILES WITH RESPONSE < 75%

FOR ANL049 Scan D

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

42

1

A16-E

29

138

-58.9

Spare fibers too close to the corners of light mixer, go back to one of the previously used fibers

42

3

A16-E

29

138

-58.9

 

QC 6 VERSION 6.0: 5-Jun-02 15:19:50

LIST OF FIBERS/TILES WITH RESPONSE < 75%

FOR ANL049 Scan E

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

42

1

A16-E

29

138

-27.7

No solution - this is as good as it gets.

42

3

A16-E

29

138

-25.9