QC 6 VERSION 6.0: 24-Jun-02 17:43:33

LIST OF FIBERS/TILES WITH RESPONSE < 80%

FOR ANL053 Scan A

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-22.4

Special tile

3

11

D4-O

2

2

-29.0

Fiber replaced

7

1

A12-O

1

18*

-21.9

Profile not in - reseated

7

1

A12-O

2

19

-46.0

On side of tile - shimmed tile

17

8

D5-O

33

50*

-31.1

The polishing was bad on this AT. It appeared that the saw bade hit the surface after the diamond bit had passed. We repolished this AT and the same thing happened. The AT was then hand polished.

The saw blade will be changed.

17

10

D5-O

33

50*

-25.0

17

8

D5-O

34

51

-25.6

17

10

D5-O

34

51

-24.3

17

8

D5-O

41

58

-35.5

17

10

D5-O

41

58

-31.7

17

8

D5-O

44

61

-21.0

17

10

D5-O

44

61

-21.4

17

8

D5-O

45

62

-34.8

17

10

D5-O

45

62

-33.2

17

8

D5-O

46

63

-39.0

17

10

D5-O

46

63

-35.7

17

8

D5-O

52

69

-40.7

17

10

D5-O

52

69

-32.3

17

8

D5-O

53

70

-22.9

17

10

D5-O

53

70

-20.9

17

8

D5-O

56

73

-37.2

17

10

D5-O

56

73

-32.9

17

9

D5-O

44

61

-23.3

17

11

D5-O

44

61

-18.9

17

9

D5-O

46

63

-30.1

17

9

D5-O

48

65

-26.4

17

11

D5-O

48

65

-42.8

17

9

D5-O

49

66*

-36.1

17

9

D5-O

52

69

-25.2

17

11

D5-O

52

69

-16.4

17

9

D5-O

53

70

-20.9

17

9

D5-O

57

74

-34.2

17

9

D5-O

62

79

-22.3

17

10

D5-O

47

64

-20.0

17

11

D5-O

1

18*

-41.9

Bad slot - shimmed

17

11

D5-O

4

21

-42.9

 

17

11

D5-O

17

34*

MISSING

Bad slot - shimmed

17

11

D5-O

44

61

-25.8

 

17

11

D5-O

46

63

-36.0

17

11

D5-O

48

65

-24.8

17

11

D5-O

52

69

-21.6

17

11

D5-O

57

74

-31.2

18

8

D5-E

44

61

-24.3

Reseated profile

18

10

D5-E

44

61

-19.3

18

9

D5-E

1

18*

-40.2

Loose profile - shimmed slot

18

9

D5-E

43

60

-75.4

Fiber replaced

18

11

D5-E

43

60

-81.4

18

9

D5-E

48

65

-28.5

Fiber replaced

18

11

D5-E

48

65

-27.4

21

1

A14-O

15

66*

-27.4

Bad slot - shimmed

21

3

A14-O

15

66*

-37.4

22

1

A14-E

14

65

-23.8

Fiber replaced

22

3

A14-E

14

65

-20.3

22

3

A14-E

15

66*

MISSING

Bad slot - shimmed

22

3

A14-E

26

77

-22.3

Fiber not centered - shimmed tile

23

6

B13-O

29

89

-22.3

Reseated profile

24

4

B13-E

23

83

-20.3

Reseated profile

24

5

B13-E

6

66*

-24.7

Loose profile - shimmed slot

24

6

B13-E

10

70

-20.6

Fiber not centered - shimmed tile

37

8

D6-O

15

97

-35.7

Fiber replaced

37

10

D6-O

15

97

-23.2

37

8

D6-O

59

141

-32.4

Fiber replaced

37

10

D6-O

59

141

-32.8

38

8

D6-E

13

95

-20.3

The polishing was bad on this AT. It appeared that the saw bade hit the surface after the diamond bit had passed. We repolished this AT and the same thing happened. The AT was then hand polished.

The saw blade will be changed.

38

8

D6-E

24

106

-42.0

38

10

D6-E

24

106

-35.9

38

8

D6-E

42

124

-22.0

38

10

D6-E

42

124

-25.3

38

8

D6-E

53

135

-21.3

38

10

D6-E

53

135

-24.2

38

8

D6-E

54

136

-24.0

38

10

D6-E

54

136

-22.4

38

8

D6-E

55

137

-25.0

38

10

D6-E

55

137

-26.3

38

8

D6-E

63

145

-26.7

38

10

D6-E

63

145

-26.4

38

9

D6-E

3

85

-21.2

38

11

D6-E

3

85

-16.0

38

9

D6-E

41

123

-25.7

38

11

D6-E

41

123

-30.2

38

9

D6-E

45

127

-25.4

38

11

D6-E

45

127

-26.8

38

9

D6-E

60

142*

-24.1

38

11

D6-E

60

142*

-18.3

38

9

D6-E

66

148

-49.8

38

11

D6-E

66

148

-47.5

38

10

D6-E

40

122

-21.9

38

10

D6-E

43

125

-22.6

38

10

D6-E

46

128

-26.1

38

10

D6-E

52

134

-20.5

41

2

A16-O

2

111

-42.9

Fiber replaced

41

2

A16-O

25

134

-85.3

Fiber replaced

42

1

A16-E

47

156

-20.4

Reseat profile

42

2

A16-E

10

119

-47.3

Replaced fiber

44

6

B15-E

18

140

-23.5

Shim tile, reseat profile

QC 6 VERSION 6.0: 28-Jun-02 15:22:21

LIST OF FIBERS/TILES WITH RESPONSE < 80% FOR

ANL053 Scan B

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

11

D4-O

2

2

-28.0

(already replaced) reseated

8

2

A12-E

9

26

-20.4

New - reseated profile

17

11

D5-O

4

21

-50.9

On side of tile - shimmed tile

17

11

D5-O

17

34*

MISSING

On side of tile - shimmed tile

18

8

D5-E

44

61

-27.1

Reseated profile

18

10

D5-E

44

61

-22.5

18

9

D5-E

60

77

-20.2

Reseated profile

21

1

A14-O

15

66*

-35.5

Replaced fiber

21

3

A14-O

15

66*

-37.6

22

1

A14-E

14

65

-26.4

(Fiber already replaced)

22

3

A14-E

14

65

-17.8

22

3

A14-E

26

77

-24.6

Reseated profile

38

8

D6-E

22

104

-22.0

New - reseated profile

38

10

D6-E

22

104

-19.9

41

2

A16-O

2

111

-22.4

reseated profile

41

2

A16-O

25

134

-24.6

reseated profile

41

3

A16-O

26

135

-20.2

reseated profile

             

QC 6 VERSION 6.0: 3-Jul-02 13:29:24

LIST OF FIBERS/TILES WITH RESPONSE < 75%

FOR ANL053 Scan C

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

11

D4-O

2

2

-29.8

Profile swapped with tile 1

22

1

A14-E

14

65

-25.1

Swap tiles with #28

41

1

A16-O

5

114*

-49.2

New - added shim & reseated

QC 6 VERSION 6.0: 3-Jul-02 12:45:59

LIST OF FIBERS/TILES WITH RESPONSE < 75%

FOR ANL053 Scan D

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

22

1

A14-E

14

65

-25.8

Fiber already replaced - no further fixes