QC 6 VERSION 6.0: 17-Sep-02 15:09:44

LIST OF FIBERS/TILES WITH RESPONSE < 80%

FOR ANL056 Scan A

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-36.2

Special Tile

4

10

D4-E

1

1

-32.0

7

1

A12-O

7

24

-24.2

Replaced fiber

7

3

A12-O

7

24

-24.9

8

1

A12-E

1

18*

-24.2

Reseated profile

9

7

B11-O

1

18*

-21.0

Special Tile

10

7

B11-E

1

18*

-20.3

11

2

A13-O

8

34*

-27.6

Replaced fiber

15

7

B12-O

4

37

-22.2

Shim tile & reseat profile

16

4

B12-E

23

56

-25.4

Replaced fiber

16

6

B12-E

23

56

-17.6

17

8

D5-O

1

18*

-21.7

Special tiles

17

9

D5-O

1

18*

-25.7

17

9

D5-O

64

81

MISSING

Replaced fiber

17

11

D5-O

64

81

MISSING

17

11

D5-O

32

49

-20.8

Reseated profile

18

8

D5-E

1

18*

-27.7

Special tile

21

1

A14-O

25

76

-21.9

Replaced fiber

21

3

A14-O

25

76

-15.4

21

2

A14-O

16

67

-22.6

Reseated profile

21

3

A14-O

15

66*

-23.0

Shim tile & reseat profile

23

5

B13-O

21

81

-57.5

Replaced fiber

23

7

B13-O

21

81

-60.7

23

6

B13-O

24

84

-20.3

Reseat profile

23

6

B13-O

28

88

-21.5

Reseat profile

29

2

A15-O

30

109

-25.9

On side of tile

30

4

A15-E

19

98

MISROUTED

B14E Tile 19 fiber - removed & rerouted

30

6

A15-E

19

98

MISROUTED

33

4

B14-O

15

105

-41.7

Reseated profile

33

4

B14-O

17

107

-22.6

Replaced fiber

33

6

B14-O

17

107

-22.3

33

7

B14-O

18

108

-22.7

Profile twisted- reseated

34

4

B14-E

2

92

-28.3

Replaced fiber

34

6

B14-E

2

92

-21.7

34

4

B14-E

19

109

MISSING

Misrouted to A15- Replace fiber

34

6

B14-E

19

109

MISSING

37

8

D6-O

29

111

-21.3

Reseated profile

37

10

D6-O

29

111

-19.2

37

9

D6-O

4

86

MISSING

Replaced fiber

37

11

D6-O

4

86

MISSING

37

10

D6-O

64

146

-23.7

Replaced fiber

38

8

D6-E

50

132

-24.0

Replaced fiber

38

10

D6-E

50

132

-22.4

41

1

A16-O

8

117

-20.2

Reseated profile

41

1

A16-O

20

129

-24.9

Replaced fiber

41

3

A16-O

20

129

-18.1

43

7

B15-O

32

154

-22.1

Cleaned slot & reseated profile

43

7

B15-O

33

155

-23.9

Cleaned slot & reseated profile

43

7

B15-O

35

157

-20.3

Cleaned slot & reseated profile

QC 6 VERSION 6.0: 2-Oct-02 13:25:14

LIST OF FIBERS/TILES WITH RESPONSE < 75% FOR

ANL056 Scan B

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-31.5

Special tile

4

10

D4-E

1

1

-29.3

17

9

D5-O

64

81

-25.6

Already replace - shim tile & reseat profile

18

8

D5-E

1

18*

-28.5

Special tile

23

5

B13-O

21

81

-25.9

Already replaced - bad gluing - replace it again

23

7

B13-O

21

81

-26.9

33

4

B14-O

17

107

-26.8

Already replaced - bad gluing - replace it again

33

6

B14-O

17

107

-23.6

34

4

B14-E

19

109

-55.4

Spot of glue on fiber - no Teflon fibers left to pull

37

8

D6-O

23

105

-33.2

Glue mess on fiber - replaced

37

10

D6-O

23

105

-29.2

38

10

D6-E

50

132

-30.4

Loose profile - reseated

41

3

A16-O

20

129

-25.7

Already replaced - clean slot & reseat profile

QC 6 VERSION 6.0: 14-Oct-02 15:20:41

LIST OF FIBERS/TILES WITH RESPONSE < 75% FOR

ANL056 Scan C

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-33.2

Special tile

4

10

D4-E

1

1

-33.8

17

9

D5-O

64

81

-28.1

New problem - reseated profile

18

8

D5-E

1

18*

-25.5

Special tile

23

5

B13-O

21

81

-34.5

Already replaced twice - no Teflon fibers left

23

7

B13-O

21

81

-27.9

34

4

B14-E

19

109

-51.7

no Teflon fibers left

37

9

D6-O

4

86

-25.7

New problem - clean slot & reseated profile

38

8

D6-E

50

132

-26.2

Fiber already replaced

38

10

D6-E

50

132

-25.9

41

1

A16-O

37

146

MISSING

New problem - broken fiber - replaced

41

3

A16-O

37

146

MISSING

QC 6 VERSION 6.0: 22-Oct-02 12:11:32

LIST OF FIBERS/TILES WITH RESPONSE < 75%

FOR ANL056 Scan D

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-32.8

Special tiles

4

10

D4-E

1

1

-30.1

17

9

D5-O

1

18*

-25.8

18

8

D5-E

1

18*

-29.4

21

2

A14-O

16

67

-29.3

New problem - Not fix

34

4

B14-E

19

109

-49.1

No Teflon fibers left - not fixed

38

8

D6-E

50

132

-26.9

Previously replaced - not replace again

38

10

D6-E

50

132

-23.0

41

2

A16-O

29

138

-27.9

New problem - not fixed

43

6

B15-O

28

150

-26.3

New problem - not fixed

43

7

B15-O

34

156

-33.0

Note: AT's A16-O, B14-O, B15-O were hand polished after scan d and 6 tiles were replaced in A15, layer 2.

QC 6 VERSION 6.0: 13-Nov-02 16:45:30

LIST OF FIBERS/TILES WITH RESPONSE < 75%

FOR ANL056 Scan E

PMT

LAYER

CELL

TILE

SLOT

%DEV

SOLUTION

             

3

10

D4-O

1

1

-32.8

Special tiles

4

10

D4-E

1

1

-30.1

17

9

D5-O

1

18*

-25.8

18

8

D5-E

1

18*

-29.4

21

2

A14-O

16

67

-28.6

Fibers already replace and no Teflon fibers remaining -

33

6

B14-O

17

107

-25.7

33

7

B14-O

26

116

-26.2

34

4

B14-E

19

109

-54.2

38

8

D6-E

50

132

-26.9

38

10

D6-E

50

132

-23.0