Before inserting the tiles, they should be inspected (in a stack of about 20 tiles):
All tiles should have similar blue color when back lit with flourescent light
Tile end surfaces should be clean and undamaged.
Tile wrappers should be approximately 2 mm below the tile end surfaces
After tiles have been inserted into the module, check that:
All tiles are the correct size and centered in slots (end surfaces should all be visible and about 4 mm below the edge of the master plates).
Tile end surfaces should be clean and undamaged.
Tile wrappers should be approximately 2 mm below the tile end surfaces.
Repair or replace any problem tiles.
Sign and date the
check sheet.Report any serious or recurrent problems.